Updated: Feb 16, 2026

Calvarial Model of Bone Augmentation in Rabbit for Assessment of Bone Growth and Neovascularization in Bone Substitution Materials
Published on: August 13, 2019
Volumetric changes following ridge preservation or spontaneous healing and early implant placement with simultaneous
Nadja Naenni1, Stefan P Bienz1, Fernando Muñoz2
1Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
Aim:
To assess volumetric and linear changes following ridge preservation (RP) or spontaneous healing plus early implant placement with or without simultaneous guided bone regeneration (GBR).
Materials And Methods:
In eight adult beagle dogs, the mesial roots of the mandibular P3, P4 and M1 were extracted. Sites were randomized to either ridge preservation (RP) or spontaneous healing (SH). Four weeks later dental implants were placed either with (RP2) or without removing non-integrated DBBM (RP1). In RP2 and SH sites, GBR was applied using a demineralized bovine bone mineral and a resorbable membrane. Impressions were taken postextraction (SH)/postridge preservation (RP1; RP2), before and after implant placement and after healing of 4 and 12 weeks. Casts were digitized to allow for superimposition and measurement of contour alterations.
Results:
Median ridge width reduction from postextraction (SH)/postridge preservation (RP1;RP2) to implant placement ranged from -13.9% (SH) to -19.7% (RP) (p > .05), whereas from implant placement to sacrifice, it was statistically significantly lower in group RP1 (-5.5%) compared to group SH (-23.4%; p = .0013) and group RP2 (-22.1%; p = .0026). Encompassing the entire study period, median ridge width changes ranged between -17.8% (SH), -24.8% (RP2) and -32.5% (RP1) (p > .05).
Conclusions:
Irrespective of the treatment modality and the healing period, part of the ridge contour was lost. Early implant placement after ridge preservation without additional GBR resulted in a more stable ridge contour after implant placement compared to controls.