Related Experiment Video
Updated: Feb 16, 2026

19:44
A Tactile Automated Passive-Finger Stimulator TAPS
Published on: June 3, 2009
14.2K
Visual and tactile feedback for a direct-manipulating tactile sensor in laparoscopic palpation
Tomohiro Fukuda1,2, Yoshihiro Tanaka1, Astrid M L Kappers3
1Department of Electrical and Mechanical Engineering, Graduate School of Engineering, Nagoya Institute of Technology, Nagoya, Japan.
Summary
This study developed a tactile sensor for laparoscopic surgery, enhancing tumor detection. Combining visual and tactile feedback improved safety and detection accuracy for surgeons.
Area of Science:
- Minimally Invasive Surgery
- Surgical Technology
- Biomedical Engineering
Background:
- Laparoscopic surgery limits surgeons' tactile sense, crucial for intraoperative tumor detection.
- Developing advanced sensory feedback is essential to overcome these limitations.
Purpose of the Study:
- To design and evaluate a novel tactile sensor for laparoscopic tumor detection.
- To assess the efficacy of visual and tactile feedback from the sensor.
Main Methods:
- A biocompatible tactile sensor was developed, providing visual (line graph) and tactile (foot force) feedback.
- Twelve novices performed tumor detection tasks under four conditions: no feedback, visual feedback, tactile feedback, and combined feedback.
Main Results:
- Visual feedback significantly improved tumor detection compared to no feedback.
- Both visual and tactile feedback enhanced surgical safety, reducing load and scanning speed.
Conclusions:
- Visual and tactile feedback show promise for improving laparoscopic palpation.
- The presentation method of feedback is critical for its effectiveness in surgical applications.
Related Concept Videos
Assessment of the Abdomen III: Palpation
3.8K
Palpation is a crucial tactile examination method for assessing abdominal organs and detecting conditions like tenderness, distention, masses, or fluid. It involves both light and deep palpation techniques, each serving specific diagnostic purposes. Light palpation helps identify tenderness and other surface-level indicators, while deep palpation locates and assess abdominal masses and organ boundaries. A skilled professional can gather valuable insights through palpation, including evaluating...
3.8K
Somatosensation
43.7K
The somatosensory system relays sensory information from the skin, mucous membranes, limbs, and joints. Somatosensation is more familiarly known as the sense of touch. A typical somatosensory pathway includes three types of long neurons: primary, secondary, and tertiary. Primary neurons have cell bodies located near the spinal cord in groups of neurons called dorsal root ganglia. The sensory neurons of ganglia innervate designated areas of skin called dermatomes.
43.7K
Tactile and Chemical Senses
890
Tactile senses encompass touch, temperature, and pain, each mediated by specific receptors. Touch receptors detect mechanical energy or pressure against the skin. Sensory fibers from these receptors enter the spinal cord and relay information to the brain stem. Here, most fibers cross over to the opposite side of the brain. The touch information then moves to the thalamus, which projects a map of the body's surface onto the somatosensory areas of the parietal lobes in the cerebral cortex.
890
Assessment of the Cardiovascular System III: Palpation
1.2K
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
1.2K
Design Example: Resistive Touchscreen
771
A device engineer plays a crucial role in designing user interfaces for mobile devices. One such interface is the resistive touchscreen, which fundamentally consists of two metallic layers: a flexible upper layer and a rigid lower layer, separated by a narrow gap. The high resistance between these two layers is a key characteristic of this design.
When a user touches the screen, the two layers make contact at a specific point known as the touchpoint. This contact reduces the resistance between...
When a user touches the screen, the two layers make contact at a specific point known as the touchpoint. This contact reduces the resistance between...
771