Analysis of Dyssynchrony and Ventricular Function in Right Univentricular Stimulation at Different Positions
Ana Paula Susin Osório1, Stefan Warpechowski1, Antonio Lessa Gaudie Ley1,2
1Programa de Pós-graduação do Instituto de Cardiologia do Rio Grande do Sul/Fundação Universitária de Cardiologia, Porto Alegre, RS, Brazil.
Introduction:
Chronic stimulation of the right ventricle with pacemaker is associated with ventricular dyssynchrony and loss of contractility, even in subjects without previous dysfunction. In these patients, there is a debate of which pacing site is less associated with loss of ventricular function.
Objective:
To compare pacemaker-induced dyssynchrony among different pacing sites in right ventricular stimulation.
Methods:
Cross-sectional study of outpatients with right ventricle stimulation higher than 80% and preserved left ventricular ejection fraction. Pacing lead position (apical, medial septum or free wall) was assessed through chest X-rays. Every patient underwent echocardiogram to evaluate for dyssynchrony according to CARE-HF criteria: aortic pre-ejection time, interventricular delay and septum/posterior wall delay on M mode.
Results:
Forty patients were included. Fifty-two percent had apical electrode position, 42% mid septum and 6% free wall. Mean QRS time 148.97±15.52 milliseconds. A weak correlation between the mean QRS width and pre-aortic ejection time (r=0.32; P=0.04) was found. No difference in QRS width among the positions could be noted. Intraventricular delay was lower in apical patients against mid septal (34.4±17.2 vs. 54.3±19.1 P<0.05) - no difference with those electrode on the free wall. No difference was noted in the pre-aortic ejection time (P=0.9).
Conclusion:
Apical pacing showed a lower interventricular conduction delay when compared to medial septum site. Our findings suggest that apical pacing dyssynchrony is not ubiquitous, as previously thought, and that it should remain an option for lead placement.
More Related Videos
06:34Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias