Abstract:
Accurate measurements of carbon monoxide's electrical properties were carried out at high pressure for the first time enabling stringent comparisons with theoretical values calculated ab initio. Dielectric permittivity measurements were conducted utilising a microwave re-entrant cavity resonator over the temperature range from (255 to 313) K and at pressures up to 8 MPa with a relative combined expanded uncertainty (k=2) less than or equal to 52 ppm. The new data enable carbon monoxide's molar polarizability to be correlated within 0.5 %, significantly improving upon existing literature data, which have a relative scatter of about 10 %. The measured molecular polarizability and electric dipole moment of carbon monoxide were determined to be 2.176×10-40 C2 m2 J-1 and 0.107 D. Literature values from ab initio calculations for these properties are within 0.28 % and 3.9 %, respectively, of the measured quantities. Moreover, our measurement of the electric dipole moment at finite temperature agrees within 2.2 % with the value derived from accurate spectroscopic measurements for the ground rovibrational state. The second dielectric virial coefficient of carbon monoxide was determined experimentally for the first time to be bϵ =(1.015±0.044) cm3 mol-1 , which compares reasonably with ab initio estimates.
More Related Videos
08:42High-Sensitivity Nuclear Magnetic Resonance at Giga-Pascal Pressures: A New Tool for Probing Electronic and Chemical Properties of Condensed Matter under Extreme Conditions
Published on: October 10, 2014
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Measurement of Air Content in Concrete
The pressure method,...
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
Pressure Gauges
Voltammetry: Factors Affecting Measurements