Background:
Airborne bacteria are a major source for wound contamination during total joint arthroplasty. Crystalline ultraviolet C (C-UVC) filter units were designed to disinfect and recirculate air in the operating room (OR). This preliminary study assessed the particle reducing capacity of C-UVC units in a highly controlled OR setting.
Methods:
A particle counter was deployed in a positive-pressure OR to measure total and viable particle counts (TPC/VPC). Thirty 23-minute experiments were performed. At 4 designated times a person would walk through the door to mimic OR traffic. Ten experiments were performed as controls, 10 experiments used a C-UVC unit 4 meters (m) from the door, and 10 cases with the C-UVC unit at 8 m. Outcomes included overall, change (Δ), and maximum TPC/VPC. Mann-Whitney U-tests determined statistical differences in TPC/VPC.
Results:
Compared to controls, the cases with the C-UVC unit at 4 m had significantly lower particle levels. Overall TPC/VPC, changes in TPC/VCP, and maximum TPC/VPC were all significantly lower (P < .05) in the C-UVC unit (4 m) group compared to the controls. The C-UVC at 8 m significantly reduced TPC in all 3 outcomes (P < .05) compared to controls; however, it did not significantly reduce changes in VPC (P = .107) and maximum VPC (P = .052). There were no significant differences in any outcomes between the 4 m and 8 m group.
Conclusion:
C-UVC units have shown to be capable of significantly reducing TPC and VPC in a highly controlled OR setting. Reducing airborne particles using C-UVC units may reduce infection rates following total joint arthroplasty.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Hand hygiene
Hand washing...