The impact of channel capture on estuarine hydro-morphodynamics and water quality in the Amazon delta

Eldo Silva Dos Santos1, Paula Patrícia Pinheiro Lopes1, Hyrla Herondina da Silva Pereira1

  • 1Rod. Juscelino Kubitschek, km.2, Bloco de Ciências Ambientais - Jardim Equatorial, Universidade Federal do Amapá, Macapá, Amapá 68903-419, Brazil.

Related Concept Videos

Quality of Water01:19

Quality of Water

In concrete preparation, the quality of water is paramount as it affects the strength and durability of the concrete. Potable water is usually preferred; however, it must not have excessive sodium or potassium to prevent compromising the concrete's integrity. Water quality is typically evaluated based on impurities such as dissolved solids, chlorides, and sulfates, and its pH value is ideally between 6 and 8. Even slightly acidic natural water may be acceptable unless it contains harmful...
581
Testing Water Quality01:14

Testing Water Quality

When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
399
The Delta-to-Delta Circuit01:17

The Delta-to-Delta Circuit

In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
1.2K
The Y-to-Delta Circuit01:19

The Y-to-Delta Circuit

A balanced wye-to-delta circuit comprises balanced Y-connected voltage sources and delta-connected loads with no neutral line connection.
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
729
The Delta-to-Y Circuit01:16

The Delta-to-Y Circuit

In the delta-wye circuit, the source is delta-connected, while the load is in a wye configuration. This means that the phase voltage of the delta-connected source is equal to the line voltage of the wye-connected load. The connection between two-line currents originates from the delta-connected source. The phase difference in the balanced system allows for calculating one line current given the other, utilizing the positive sequence of phases. In the delta-wye system, the phase currents in the...
935
Ion Channels01:19

Ion Channels

The movement of ions like sodium, potassium, and calcium into and out of the cell is essential to maintain the electrochemical gradient in living cells. The ion channels—a class of membrane transport proteins—help maintain this ionic gradient for the smooth functioning of physiological activities such as maintaining cell size and volume, conducting nerve impulses, and gas and nutrient exchange.
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...
91.6K