Related Experiment Video
Updated: Feb 16, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
How Well Does Dual-energy CT with Fast Kilovoltage Switching Quantify CT Number and Iodine and Calcium
Shingo Ohira1, Tsukasa Karino2, Yoshihiro Ueda3
1Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka 541-8567, Japan; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan.
Rationale And Objectives:
Because it is imperative for understanding the performance of dual-energy computed tomography scanner to determine clinical diagnosis, we aimed to assess the accuracy of quantitative measurements using dual-energy computed tomography with fast kilovoltage switching.
Materials And Methods:
Quantitative measurements were performed for 16 reference materials (physical density, 0.965-1.550 g/cm3; diameter of rod, 2.0-28.5 mm; iodine concentration, 2-15 mg/mL; and calcium concentration, 50-300 mg/mL) with varying scanning settings, and the measured values were compared to their theoretical values.
Results:
For high-density material, the maximum differences in Hounsfield unit values in the virtual monochromatic images at 50, 70, and 100 keV were -176.2, 61.0, and -35.2 HU, respectively, and the standard deviations over short- and long-term periods were 11.1, 6.1, and 3.5 HU at maximum. The accuracy of the Hounsfield unit measurement at 50 and 70 keV was significantly higher (P < 0.05) with higher radiation output and smaller phantom size. The difference in the iodine and calcium measurements in the large phantom were up to -2.6 and -60.4 mg/mL for iodine (5 mg/mL with 2-mm diameter) and calcium (300 mg/mL) materials, and the difference was improved with a small phantom. Metal artifact reduction software improved subjective image quality; however, the quantitative values were significantly underestimated (P < 0.05) (-49.5, -26.9, and -15.3 HU for 50, 70, and 100 keV, respectively; -1.0 and -17 mg/mL for iodine and calcium concentration, respectively) compared to that acquired without a metal material.
Conclusions:
The accuracy of quantitative measurements can be affected by material density and the size of the object, radiation output, phantom size, and the presence of metal materials.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Feedback Regulation of Calcium Concentration
Various transmembrane receptors, such as G protein-coupled receptors (GPCRs), elicit a response to extracellular signals by increasing cytosolic calcium. Activated GPCRs...
Switching of BJT
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...

