Breast Imaging Outcomes following Abnormal Thermography
Colleen H Neal1, Kelsey A Flynt1, Deborah O Jeffries1
1Department of Radiology, University of Michigan, C415 MIB SPC 5842, 1500 E. Medical Center Drive, Ann Arbor, MI, 48109.
Rationale And Objectives:
The study aimed to determine the outcome of patients presenting for evaluation of abnormal breast thermography.
Materials And Methods:
Following Institutional Review Board approval, retrospective search identified 38 patients who presented for conventional breast imaging following a thermography-detected abnormality. Study criteria included women who had mammogram and/or breast ultrasound performed for evaluation of a thermography-detected abnormality between January 1, 2000, and December 31, 2015. Patients whose mammograms and ultrasounds were initiated at an outside institution or who did not have imaging at our institution were excluded. Records were reviewed for clinical history, thermography results, mammogram and/or ultrasound findings, and pathology. Mammograms and ultrasounds were prospectively interpreted by one of 14 Mammography Quality Standards Act-certified breast imaging radiologists with 3-30 years of experience. Patient outcomes were determined by biopsy or at least 1 year of follow-up. Patient ages ranged from 23 to 70 years (mean = 50 years).
Results:
Ninety-five percent (36 of 38) of patients did not have breast cancer. The two patients diagnosed with breast cancer had suspicious clinical symptoms including palpable mass and erythema. No asymptomatic woman had breast cancer. Negative predictive value was 100%. Of 38 patients, 79% (30 of 38) had Breast Imaging Reporting and Data System (BI-RADS) 1 or 2 assessments; 5% (2 of 38) had BI-RADS 3; and 16% (6 of 38) had BI-RADS 4 (n = 5) or BI-RADS 5 (n = 1) assessments. Two of six patients with biopsy recommendations were diagnosed with breast cancer (Positive predictive value 2 = 33.3%). All findings recommended for biopsy were ipsilateral to the reported thermography abnormality.
Conclusions:
No cancer was diagnosed among asymptomatic women. The 5% of patients diagnosed with cancer had co-existing suspicious clinical findings. Mammogram and/or ultrasound were useful in accurately characterizing patients with abnormal thermography.
Related Concept Videos
Abnormal Proliferation
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Guidelines for Writing Outcome
Patient outcomes reflect the patient's response to the goal rather than what the nurse aims to achieve. Terminology should be observable and measurable to avoid the reader's interpretation. The desired outcome should be realistic and achievable in the designated care timeframe. Expected outcomes should align with adjunctive therapies. The outcome should enhance care...