Related Experiment Video
Updated: Feb 16, 2026

Synthesis and Microdiffraction at Extreme Pressures and Temperatures
Published on: October 7, 2013
Isolation of strawberry anthocyanins using high-speed counter-current chromatography and the copigmentation with
Hui Zou1, Yan Ma2, Zhenzhen Xu3
1College of Food Science and Nutritional Engineering, China Agricultural University, Beijing Advanced Innovation Center for Food Nutrition and Human Health, National Engineering Research Centre for Fruit and Vegetable Processing, Key Lab of Fruit and Vegetable Processing, Ministry of Agriculture, Beijing Key Laboratory for Food Nonthermal Processing, Beijing 100083, China; Institute of Quality Standard & Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Key Laboratory of Agro-food Safety and Quality, Ministry of Agriculture, Beijing 100081, China.
Abstract:
Three anthocyanins were isolated from strawberry extract by high-speed counter-current chromatography, using a biphasic mixture of tert-butyl methyl ether, n-butanol, acetonitrile, water and trifluoroacetic acid (2.5:2.0:2.5:5.0:1.0%). The anthocyanins were identified as pelargonidin-3-rutinoside, cyanidin-3-glucoside and pelargonidin-3-glucoside with purity of 95.6%, 96.2% and 99.3% respectively. Additionally, the copigmentation reaction rates between pelargonidin-3-glucoside and phenolic acids (catechin or epicatechin) at pH 1.5 and 3.6, pressure 0.1 and 500 MPa, and temperature 60 °C were calculated. The absorbance of pelargonidin-3-glucoside at pH 3.6, with high quantity of phenolic acids was significantly increased by high pressure. The complex of pelargonidin-3-glucoside/catechin has a binding energy of 78.64 kJ/mol at pH 3.6, and 39.13 kJ/mol at pH 1.5; pelargonidin-3-glucoside/epicatechin has a binding energy of 75.34 kJ/mol at pH 1.5 and 54.47 kJ/mol at pH 3.6. The hydrogen bond and van der Waals interaction were the main forces contributing to the structures of complex.
More Related Videos
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
07:06Wicking Tests for Unidirectional Fabrics: Measurements of Capillary Parameters to Evaluate Capillary Pressure in Liquid Composite Molding Processes
Published on: January 27, 2017
Related Concept Videos
Pressure and Volume in an Adiabatic Process
High-Performance Liquid Chromatography: Elution Process
Cyclic Processes And Isolated Systems
In the case of a non-isolated system, the change in the internal energy is zero only if the process is cyclic. A thermodynamic process is considered cyclic if the system undergoes a series of changes and returns to its initial state.
Consider a cyclic process that returns to its initial state, undergoing a four-step process. The heat transfer along each...
Speed of Sound in Gases
Speed of a Transverse Wave
One of the key properties of any wave is the wave speed. Light...
Distribution of Molecular Speeds