Fine-tuning the normal tissue objective in eclipse for lung stereotactic body radiation therapy
James P Bell1, Pretesh Patel2, Kristin Higgins2
1Department of Radiation Oncology, Simmons Comprehensive Cancer Center at the University of Texas Southwestern Medical Center, Dallas, TX.
Abstract:
The purpose of this study was to characterize the effects of the normal tissue objective (NTO) on lung stereotactic body radiation therapy (SBRT) dose distributions. The NTO is a spatially varying constraint used in Eclipse to limit dose to normal tissues by steepening the dose gradient. However, the multitude of potential NTO setting combinations challenges optimal NTO tuning. In the present study, a broad range of NTO settings are investigated for lung SBRT treatment planning with volumetric modulated arc therapy(VMAT). Ten prior lung SBRT cases were replanned using NTO priorities of 1, 50, 100, 200, 500, and 999 in combination with fall-off values of 0.01, 0.05, 0.10, 0.15, 0.20, 0.30, 0.50, 1.00, and 5.00 mm-1 and the automatic NTO. NTO distances to planning target volume (PTV), start dose, and end dose were 1 mm, 100%, and 10%, respectively, for all 600 plans. Prescription dose covered 95% of the PTV. The following metrics were recorded: conformity index (CI), ratio of the 50% prescription isodose volume to PTV (R50%), maximum dose 2 cm away from PTV (D2cm), lung volume of ≥20 Gy (V20Gy), maximum PTV dose (PTVmax), and monitor units (MUs). Differences between prior plans and NTO plans were evaluated using the Wilcoxon signed-rank test. Different combinations of NTO settings resulted in wide-ranging plan quality metrics: CI (1.00 to 1.54), R50% (3.95 to 7.57), D2cm (33.4% to 67.9%), V20Gy (1.66% to 2.75%), MU (1.81 cGy-1 to 4.69 cGy-1), and PTVmax (118% to 175%). Although no settings were optimal for all metrics, a fall-off of 0.15 mm-1 and a priority of 500 best satisfied institutional criteria. Compared with prior plans, NTO plans resulted in significantly lower R50% (4.00 vs 4.35, p = 0.002), lower V20Gy (1.22% vs 1.32%, p = 0.006), and higher PTVmax (138% vs 122%, p = 0.002). All of the prior and well-tuned NTO plans met Radiation Therapy Oncology Group (RTOG) 0813 guidelines. Lung SBRT dose distributions were characterized across a range of NTO settings. NTO plans with well-tuned settings compared favorably with prior plans.
Related Concept Videos
Biological Effects of Radiation
Lung Capacity
Fineness of Cement
Direct...
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Stem Cell Therapy for Tissue Regeneration
Types of Stem Cells used in Stem Cell Therapy
The two main cell...
Gene Therapy