Twenty-four hour intraocular pressure measurements and home tonometry
Frances Meier-Gibbons1, Michael S Berlin2, Marc Töteberg-Harms3
1Eye Center Rapperswil, Merkurstrasse 50, Rapperswil, Switzerland.
Purpose Of Review:
IOP is the only treatable risk factor contributing to glaucoma and most management and treatment of glaucoma is based on IOP. However, current IOP measurements are limited to office hours and control of glaucoma in many patients would benefit from the ability to monitor IOP diurnally so as not to miss abnormal pressures, which occur outside of office hours Consequently, to improve patient care, the ability to enable accurate and minimally disruptive diurnal IOP monitoring would improve caring for these patients.
Recent Findings:
The studies we selected for this review can be divided into three categories: self-/home-tonometry, continuous invasive intraocular pressure measurements, and continuous noninvasive ocular measurements.
Summary:
The desire to obtain better insight in our patients' true diurnal IOP has led to the development of home-tonometers, in addition to extraocular and intraocular continuous pressure measurement devices. All of the devices have respective advantages and disadvantages, but none to date completely fulfills the goal of providing a true diurnal IOP profile.Video abstracthttp://links.lww.com/COOP/A27.
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Holter Monitor: 24-Hour Monitoring
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.