Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Improved segmental myocardial strain reproducibility using deformable registration algorithms compared with feature
Jie Wang1, Weihao Li1, Jiayu Sun2
1Department of Cadiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
Background:
Segmental myocardial strain using feature tracking (FT) cardiac MRI is not acceptable due to poor reproducibility.
Purpose:
To assess the reproducibility of left ventricle (LV) segmental myocardial strain measured by deformation registration algorithm (DRA).
Study Type:
Prospective clinical trial.
Subjects:
Sixteen healthy volunteers and 28 hypertrophic cardiomyopathy (HCM) patients.
Field Strength/Sequence:
Retrospective ECG gating cardiac MRI imaging was performed at 3.0T with a steady-state free precession (SSFP) sequence.
Assessment:
LV global and segmental myocardial strains were analyzed by DRA, FT, and speckle tracking echocardiography (STE) by two experienced observers and the reproducibility of global and segmental strains were compared.
Statistical Tests:
Reproducibility was tested by coefficient of variation (COV) and intraclass correlation coefficient (ICC). Receiver operator curves as well as comparison of areas under the curve (AUC) were analyzed.
Results:
DRA showed the best observer agreement on segmental strain evaluated by ICC, LS (longitudinal strain): intraobserver variability range (0.98,1.00), interobserver variability range (0.83,0.92), CS (circumferential strain): intraobserver variability range (0.90,0.99), interobserver variability range (0.80,0.97), RS (radial strain): intraobserver variability range (0.84,0.99), interobserver variability range (0.85,0.99). Segmental LS, CS, and RS agreements evaluated by COV for FT and STE were poor. LV global myocardial strain of HCM was significantly lower than controls for all applied techniques, but global CS by DRA had better accuracy compared to FT or STE for distinguishing HCM from healthy subjects: AUC 0.880 (DRA) vs. 0.577 (FT) or 0.736 (STE), P < 0.05.
Data Conclusions:
DRA is a reliable and robust analysis tool for segmental myocardial strain. Global CS by DRA allows discrimination between HCM and normal controls with better accuracy compared with FT and STE.
Level Of Evidence:
1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2018;48:404-414.
Related Concept Videos
Plastic Deformations
Plastic Deformations
Trial and Error and Algorithm
Temperature Dependent Deformation
Deformations in a Symmetric Member in Bending
When the member is segmented into tiny cubic elements, it is observed that the primary stress...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...