Related Experiment Video
Updated: Feb 16, 2026

Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
Post-TAVI Follow-Up with MDCT of the Valve Prosthesis: Technical Application, Regular Findings and Typical Local
Martin Soschynski1, Fabio Capilli1, Philipp Ruile2
1Department of Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, Freiburg, Germany.
Background:
Transcatheter aortic valve implantation (TAVI) has evolved into an alternative procedure to surgical valve replacement for high-risk patients with aortic valve stenosis. Despite technical innovations, there is still a risk of complications during and after the intervention. After a TAVI procedure, ECG-gated multidetector computed tomography (MDCT) plays an important role in the early diagnosis of local complications. In this article, we explain for the first time how the technical acquisition of MDCT in the region of the aortic root is performed as post-interventional control of the TAVI prosthesis. In the second part normal post-interventional findings of different prosthetic valves as well as classic and uncommon complications in the implant area will be illustrated in several case studies.
Methods:
In this review the current literature from PubMed about ECG-gated MDCT after TAVI is summarized and structured. It is supplemented by several case studies from our institution.
Results And Conclusion:
Using retrospectively ECG-gated MDCT, an aortic valve prosthesis after TAVI can be visualized with high spatial resolution in several phases of the cardiac cycle. Images of the implanted aortic valve at all time points of the cardiac cycle enable a functional analysis of prosthetic leaflets similar to echocardiography. MDCT is superior to transthoracic echocardiography with respect to the direct detection of prosthetic leaflet thrombosis. The position of the device in relation to the coronary ostia and correct unfolding of the stent frame need to be evaluated. There are different types of stents carrying the valve leaflets with distinct ideal positions. Any stent should cover the left ventricular outflow tract (LVOT) along its whole circumference. Life-threatening complications in the implant area, such as annulus rupture, can be diagnosed reliably with CT.
Key Points:
· ECG-gated multidetector CT (MDCT) after transcatheter aortic valve implantation (TAVI) can provide early detection of postinterventional complications of the prosthetic valve and the aortic root.. · MDCT is superior to echocardiography with respect to the direct detection of prosthetic leaflet thrombosis.. · MDCT can also reveal hypokinesia of the thrombotic valve leaflets.. · Correct position of the device und unfolding of the stent frame differ according to the type of prosthesis.. · The integrity of the native aortic root should be carefully assessed..
Citation Format:
· Soschynski M, Capilli F, Ruile P et al. Post-TAVI Follow-Up with MDCT of the Valve Prosthesis: Technical Application, Regular Findings and Typical Local Post-Interventional Complications. Fortschr Röntgenstr 2018; 190: 521 - 530.
Related Concept Videos
Post-traumatic Stress Disorder
Symptoms and Behavioral Manifestations
A spectrum of distressing symptoms characterizes PTSD. Recurrent flashbacks, where individuals involuntarily relive traumatic events,...
Post-translational Translocation of Proteins to the RER
Targeting proteins to the ER
Hsp40 and Hsp70 chaperone molecules bind the translated proteins in the cytosol to prevent their folding. The chaperone binding helps to keep the signal...
Handwashing III: During the Procedure and Post-Procedure Steps
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Local Anesthetics: Common Agents and Their Applications
Cocaine is an ester of benzoic acid and methylecgogine. It is used to anesthetize and vasoconstrict locally. Currently, it is used primarily for topical applications. It is beneficial for surgeries on the upper respiratory tract, providing anesthesia and shrinking the mucosa. Cocaine in the form of cocaine hydrochloride is...
Typical Model Studies