Centrifugation-free washing: A novel approach for removing immunoglobulin A from stored red blood cells

Eszter Vörös1, Nathaniel Z Piety1, Briony C Strachan1

  • 1Department of Biomedical Engineering, University of Houston, Houston, Texas 77204.

Washed red blood cells (RBCs) are indicated for immunoglobulin A (IgA) deficient recipients. Centrifugation-based cell processors commonly used by hospital blood banks cannot consistently reduce IgA below the recommended levels, hence double washing is frequently required. Here, we describe a prototype of a simple, portable, disposable system capable of washing stored RBCs without centrifugation, while reducing IgA below 0.05 mg/dL in a single run. Samples from RBC units (n = 8, leukoreduced, 4-6 weeks storage duration) were diluted with normal saline to a hematocrit of 10%, and then washed using either the prototype washing system, or via conventional centrifugation. The efficiency of the two washing methods was quantified and compared by measuring several key in vitro quality metrics. The prototype of the washing system was able to process stored RBCs at a rate of 300 mL/hour, producing a suspension of washed RBCs with 43 ± 3% hematocrit and 86 ± 7% cell recovery. Overall, the two washing methods performed similarly for most measured parameters, lowering the concentration of free hemoglobin by >4-fold and total free protein by >10-fold. Importantly, the new washing system reduced the IgA level to 0.02 ± 0.01 mg/mL, a concentration 5-fold lower than that produced by conventional centrifugation. This proof-of-concept study showed that centrifugation may be unnecessary for washing stored RBCs. A simple, disposable, centrifugation-free washing system could be particularly useful in smaller medical facilities and resource limited settings that may lack access to centrifugation-based cell processors.

Related Concept Videos

Immunoglobulin-like Cell Adhesion Molecules01:31

Immunoglobulin-like Cell Adhesion Molecules

Immunoglobulin-like cell adhesion molecules or Ig-CAMs are a versatile group of cell surface glycoproteins belonging to the immunoglobulin protein superfamily. Ig-CAMs possess the characteristic immunoglobulin protein domains and other domains such as the fibronectin type III domain. The Ig domains are glycosylated to varying degrees in different Ig-CAMs.
Ig-CAMs exhibit either homophilic binding (to other Ig-CAMs) or heterophilic binding (to other ligands such as integrins). While most Ig-CAMs...
4.4K
Centrifugation01:05

Centrifugation

Centrifugation is a separation technique based on differences in density or size. It is commonly used to separate solids from aqueous interferents. During centrifugation, the sample is placed in centrifugation tubes and spun at high angular velocity, which allows centrifugal force to act differentially on the different densities or masses of the components. After spinning, the supernatant liquid is decanted. Depending on the specific application, either the pellet or the supernatant is retained...
8.3K
Energy Stored in a Capacitor01:12

Energy Stored in a Capacitor

When an archer pulls the string in a bow, he saves the work done in the form of elastic potential energy. When he releases the string, the potential energy is released as kinetic energy of the arrow. A capacitor works on the same principle in which the work done is saved as electric potential energy. The potential energy (UC) could be calculated by measuring the work done (W) to charge the capacitor.
4.8K
Washing, Drying, and Ignition of Precipitates00:52

Washing, Drying, and Ignition of Precipitates

After filtration, the precipitate is washed to remove coprecipitated impurities and any remaining mother liquor. Colloidal precipitates, such as silver chloride, are washed with an electrolyte (such as dilute nitric acid) to prevent the peptization of the precipitate. In the case of slightly soluble precipitates, the wash solution contains a common ion to reduce solubility. Lead sulfate, which is slightly soluble in water, is washed with dilute sulfuric acid. Similarly, wash solutions may be...
6.8K
Energy Stored in Capacitors01:10

Energy Stored in Capacitors

A parallel plate capacitor, when connected to a battery, develops a potential difference across its plates. This potential difference is key to the operation of the capacitor, as it determines how much electrical energy the capacitor can store.
By integrating the equation that relates voltage and current in a capacitor, one can derive an equation for the voltage across the capacitor at any given time. This equation is crucial in understanding and predicting the behavior of capacitors in...
1.2K
Energy Stored in Inductors01:16

Energy Stored in Inductors

An inductor is ingeniously crafted to accumulate energy within its magnetic field. This field is a direct result of the current that meanders through its coiled structure. When this current maintains a steady state, there is no detectable voltage across the inductor, prompting it to mimic the behavior of a short circuit when faced with direct current.
In terms of gauging the energy stored within an inductor, it is equivalent to the integral of the power delivered at every individual moment, all...
976