Variance components associated with long-echo-time MR spectroscopic imaging in human brain at 1.5T and 3T
Michael J Thrippleton1, Jehill P Parikh1, Scott I K Semple2
1Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, United Kingdom.
Object:
Magnetic resonance spectroscopic imaging (MRSI) is increasingly used in medicine and clinical research. Previous reliability studies have used small samples and focussed on limited aspects of variability; information regarding 1.5T versus 3T performance is lacking. The aim of the present work was to measure the inter-session, intra-session, inter-subject, within-brain and residual variance components using both 1.5T and 3T MR scanners.
Materials And Methods:
Eleven healthy volunteers were invited for MRSI scanning on three occasions at both 1.5T and 3T, with four scans acquired at each visit. We measured variance components, correcting for grey matter and white matter content of voxels, of metabolite peak areas and peak area ratios.
Results:
Residual variance was in general the largest component at 1.5T (8.6-24.6%), while within-brain variation was the largest component at 3T (12.0-24.7%). Inter-subject variation was around 5%, while inter- and intra-session variance were both generally small.
Conclusion:
Multiple variance contributions associated with MRSI measurements were quantified and the performance of 1.5T and 3T MRI scanners compared using data from the same group of subjects. Residual error is much lower at 3T, but other variance components remain important.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Variance
The standard deviation measures the spread in the same units as the data....
Friedman Two-way Analysis of Variance by Ranks
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Components of Language
Components of Stress
Interestingly, the hidden cube faces also experience these stresses, equal and...