Validation of a three-dimensional body scanner for body composition measures
Michelle M Harbin1, Alexander Kasak2, Joseph D Ostrem3
1Laboratory of Integrative Human Physiology, School of Kinesiology, University of Minnesota, Minneapolis, MN, 55455, USA. harb0085@umn.edu.
An infrared 3D body scanner underestimated body fat percentage compared to traditional methods like hydrostatic weighing. Its accuracy decreases with higher adiposity, requiring algorithm adjustments for reliable body composition analysis.
Area of Science:
- Anthropometry
- Body Composition Analysis
- Biotechnology
Background:
- Accurate body composition assessment is crucial for health and fitness evaluations.
- Traditional methods like hydrostatic weighing (HW) and bioelectrical impedance analysis (BIA) have limitations.
- Emerging technologies like 3D scanning offer potential for non-invasive body composition measurement.
Purpose of the Study:
- To evaluate the accuracy of an infrared 3D body scanner for determining body fat percent (BF%) in adults.
- To compare the 3D scanner's BF% measurements against established methods: HW, BIA, skinfolds, and girths.
- To identify potential discrepancies and limitations of the 3D scanning technology in body composition analysis.
Main Methods:
- A study involving 265 adults (119 males) with diverse body mass index (BMI) values.
- BF% was measured using an infrared 3D body scanner, HW, BIA, skinfolds, and girth measurements.
- Statistical analysis included repeated measures ANOVA and multivariate ANOVA to compare methods and assess effects of sex and method.
Main Results:
- Significant differences in BF% were found among all measurement methods (p < 0.001).
- The 3D scanner yielded significantly lower BF% (18.1%) compared to HW (22.8%), BIA (20.1%), skinfolds (19.7%), and girths (21.2%).
- 3D scanner precision diminished with increasing adiposity, suggesting algorithmic inconsistencies.
Conclusions:
- The infrared 3D body scanner currently underestimates BF% when compared to established methods.
- The technology's accuracy is compromised at higher levels of adiposity.
- A correction factor within the 3D scanner's algorithm is necessary to improve its validity for body composition assessment.
Related Concept Videos
Composite Bodies
Composite bodies have widespread applications in mechanical engineering, from automobiles to aircraft to rockets. For example, an automobile wheel comprises...
Composition of Body Fluids
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Body Temperature
Body Temperature
The average body temperature is approximately 37°C (98.6°F) and typically ranges from 36.1–37.2°C...
Centroid of a Body
For a homogeneous body with constant density, the centroid can usually be found using equations representing a balance of the moments of the body's volume. If the...