Study Objective:
To assess if follow-up confirmation testing 3 months after hysteroscopic sterilization with the Essure device (Bayer HealthCare Pharmaceuticals, Inc., Whippany, NJ) improved with recommendation for transvaginal ultrasound (TVUS) versus hysterosalpingogram (HSG).
Design:
Retrospective, observational case-controlled cohort study (Canadian Task Force classification II-2).
Setting:
Two-physician private practice in Evansville, Indiana.
Patients:
Compliance rates for a TVUS confirmation test on 100 women who underwent hysteroscopic sterilization compared with a previously published cohort of 1004 women who were scheduled to undergo an HSG confirmation test.
Intervention:
Acquisition of 3-month confirmation testing after Essure hysteroscopic sterilization.
Measurement And Main Results:
All women who underwent Essure hysteroscopic sterilization with recommendation for TVUS confirmation testing between July 2015 and January 2017 were compared with a previously published cohort of 1004 patients with recommendation for HSG confirmation testing (HSG cohort). In addition, an HSG subgroup cohort (HSG subgroup) similar in size and closest chronology to the TVUS cohort was drawn from the original 1004 patients and analyzed for HSG follow-up. Records for all patients were reviewed for demographic, procedural, and confirmation testing and outcome data. One hundred patients were identified with successful Essure device placement and a recommendation for TVUS confirmation testing. Eighty-eight patients (88.0%) returned for TVUS at 3 months. In the HSG cohort 1004 successful Essure devices were placed, and 778 patients returned for the recommended HSG follow-up (77.5%). There was a significantly higher follow-up rate for TVUS compared with the HSG cohort (88.0% vs 77.5%, p = .008). In the HSG subgroup 184 patients were identified, and 133 patients presented for HSG follow-up (72.3%), indicating a significantly higher follow-up rate in the TVUS cohort (88.0% vs 72.3%, p = .001). No pregnancies after any confirmation testing were noted.
Conclusion:
Confirmation testing with TVUS rather than HSG 3 months after Essure device placement results in increased patient compliance that may lead to improved patient outcomes with reduction of unintended pregnancy.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Related Rates