Test-retest reliability of myelin imaging in the human spinal cord: Measurement errors versus region- and
Simon Lévy1,2, Marie-Claude Guertin3, Ali Khatibi2,4,5,6
1NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, QC, Canada.
Purpose:
To implement a statistical framework for assessing the precision of several quantitative MRI metrics sensitive to myelin in the human spinal cord: T1, Magnetization Transfer Ratio (MTR), saturation imposed by an off-resonance pulse (MTsat) and Macromolecular Tissue Volume (MTV).
Methods:
Thirty-three healthy subjects within two age groups (young, elderly) were scanned at 3T. Among them, 16 underwent the protocol twice to assess repeatability. Statistical reliability indexes such as the Minimal Detectable Change (MDC) were compared across metrics quantified within different cervical levels and white matter (WM) sub-regions. The differences between pathways and age groups were quantified and interpreted in context of the test-retest repeatability of the measurements.
Results:
The MDC was respectively 105.7ms, 2.77%, 0.37% and 4.08% for T1, MTR, MTsat and MTV when quantified over all WM, while the standard-deviation across subjects was 70.5ms, 1.34%, 0.20% and 2.44%. Even though particular WM regions did exhibit significant differences, these differences were on the same order as test-retest errors. No significant difference was found between age groups for all metrics.
Conclusion:
While T1-based metrics (T1 and MTV) exhibited better reliability than MT-based measurements (MTR and MTsat), the observed differences between subjects or WM regions were comparable to (and often smaller than) the MDC. This makes it difficult to determine if observed changes are due to variations in myelin content, or simply due to measurement error. Measurement error remains a challenge in spinal cord myelin imaging, but this study provides statistical guidelines to standardize the field and make it possible to conduct large-scale multi-center studies.
Insights
Quantitative MRI metrics for spinal cord myelin, including T1, Magnetization Transfer Ratio (MTR), and Macromolecular Tissue Volume (MTV), show measurement errors comparable to biological differences. This highlights challenges in spinal cord myelin imaging and suggests standardized statistical guidelines are needed for multi-center studies.
Area of Science:
- Neuroimaging
- Biomedical Engineering
- Quantitative MRI
Background:
- Myelin imaging in the human spinal cord is crucial for understanding neurological diseases.
- Quantitative Magnetic Resonance Imaging (qMRI) metrics like T1, Magnetization Transfer Ratio (MTR), saturation imposed by an off-resonance pulse (MTsat), and Macromolecular Tissue Volume (MTV) are sensitive to myelin content.
- Assessing the precision and reliability of these metrics is essential for clinical applications.
Purpose of the Study:
- To establish a statistical framework for evaluating the precision of T1, MTR, MTsat, and MTV in the human spinal cord.
- To compare the reliability of different myelin-sensitive MRI metrics across various spinal cord regions and age groups.
Main Methods:
- Thirty-three healthy subjects (young and elderly) underwent 3T MRI scans.
- Sixteen subjects were rescanned to assess test-retest repeatability.
- Statistical reliability indexes, including Minimal Detectable Change (MDC), were calculated for each metric within different white matter (WM) sub-regions.
Main Results:
- The Minimal Detectable Change (MDC) values for T1, MTR, MTsat, and MTV were 105.7ms, 2.77%, 0.37%, and 4.08%, respectively.
- Observed differences between white matter regions or age groups were often comparable to or smaller than the MDC.
- No significant differences in metrics were found between young and elderly age groups.
Conclusions:
- T1-based metrics (T1 and MTV) demonstrated better reliability than MT-based measurements (MTR and MTsat).
- Measurement error is a significant challenge in spinal cord myelin imaging, potentially obscuring true biological variations.
- The study provides statistical guidelines to standardize spinal cord myelin imaging and facilitate large-scale, multi-center research.
Related Concept Videos
Reliability and Validity
Spinal Cord
The Spinal Cord
Spinal Cord: Information Processing
Sensory Information Processing
Sensory information processing begins at the sensory receptors located in the skin and other tissues, which detect somatic sensory stimuli such as touch, temperature, or pain. These receptors function as catalysts, initiating...
Spinal Cord: Gross Anatomy
Spinal Cord: Cross-sectional Anatomy
Gray Matter and its Components
Central to the gray matter is...