Related Experiment Video
Updated: Feb 16, 2026

Developing a Virtual Reality Video Game to Simulate Rip Currents
Published on: July 16, 2020
Development of an objective assessment tool for total laparoscopic hysterectomy: A Delphi method among experts and
Sophie Knight1, Rajesh Aggarwal2,3, Aubert Agostini1
1Department of Obstetrics and Gynecology, Assistance Publique-Hôpitaux de Marseille, La Conception Hospital, Marseille, Aix Marseille Université, France.
Introduction:
Total Laparoscopic hysterectomy (LH) requires an advanced level of operative skills and training. The aim of this study was to develop an objective scale specific for the assessment of technical skills for LH (H-OSATS) and to demonstrate feasibility of use and validity in a virtual reality setting.
Material And Methods:
The scale was developed using a hierarchical task analysis and a panel of international experts. A Delphi method obtained consensus among experts on relevant steps that should be included into the H-OSATS scale for assessment of operative performances. Feasibility of use and validity of the scale were evaluated by reviewing video recordings of LH performed on a virtual reality laparoscopic simulator. Three groups of operators of different levels of experience were assessed in a Marseille teaching hospital (10 novices, 8 intermediates and 8 experienced surgeons). Correlations with scores obtained using a recognised generic global rating tool (OSATS) were calculated.
Results:
A total of 76 discrete steps were identified by the hierarchical task analysis. 14 experts completed the two rounds of the Delphi questionnaire. 64 steps reached consensus and were integrated in the scale. During the validation process, median time to rate each video recording was 25 minutes. There was a significant difference between the novice, intermediate and experienced group for total H-OSATS scores (133, 155.9 and 178.25 respectively; p = 0.002). H-OSATS scale demonstrated high inter-rater reliability (intraclass correlation coefficient [ICC] = 0.930; p<0.001) and test retest reliability (ICC = 0.877; p<0.001). High correlations were found between total H-OSATS scores and OSATS scores (rho = 0.928; p<0.001).
Conclusion:
The H-OSATS scale displayed evidence of validity for assessment of technical performances for LH performed on a virtual reality simulator. The implementation of this scale is expected to facilitate deliberate practice. Next steps should focus on evaluating the validity of the scale in the operating room.
Related Concept Videos
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
Development of Analytical Methods
Velocity of an Object
Potential Due to a Polarized Object
Potential Due to a Magnetized Object
The vector...
Principle of Virtual Work: Problem Solving
To apply the principle of virtual work,...

