Related Experiment Video
Updated: Feb 16, 2026

10:49
Laboratory-determined Phosphorus Flux from Lake Sediments as a Measure of Internal Phosphorus Loading
Published on: March 6, 2014
17.9K
Calibration of the APEX Model to Simulate Management Practice Effects on Runoff, Sediment, and Phosphorus Loss
Journal of Environmental Quality
|January 3, 2018
Summary
Agricultural models like APEX accurately simulate Phosphorus (P) loss within calibration managements. However, using these models outside their original management data significantly reduces accuracy, highlighting the need for broader calibration datasets.
Area of Science:
- Environmental Science
- Agricultural Engineering
- Computational Modeling
Background:
- Process-based computer models are increasingly used for Phosphorus (P) Index assessment.
- The reliability of models simulating P loss under novel agricultural managements remains largely untested.
Purpose of the Study:
- To evaluate the Agricultural Policy Environmental eXtender (APEX) model's accuracy in simulating P loss with varying managements.
- To assess model performance when applied to data outside its calibration set.
Main Methods:
- APEX model calibration using field-scale data from eight managements across two locations.
- Validation of management-specific and location-wide models against observed runoff, sediment, total P, and dissolved P loss.
- Performance evaluation using Nash-Sutcliffe efficiency and percent bias metrics.
Main Results:
- Management-specific APEX models achieved satisfactory performance (>0.50 NSE, ±35% bias for runoff) within their calibration managements.
- Model accuracy decreased substantially when applied to different managements, meeting criteria in only one-third of tests.
- Location models, calibrated with diverse management data, demonstrated superior performance across all tested managements compared to management-specific models.
Conclusions:
- APEX model predictions for P loss are reliable only within the scope of the calibration management.
- Broadening calibration datasets to include multiple management systems improves model applicability for assessing P loss and P Index evaluation.
- Caution is advised when extrapolating model results beyond their calibrated management conditions.
Related Concept Videos
The Phosphorus Cycle
44.3K
Unlike carbon, water, and nitrogen, phosphorus is not present in the atmosphere as a gas. Instead, most phosphorus in the ecosystem exists as compounds, such as phosphate ions (PO43-), found in soil, water, sediment and rocks. Phosphorus is often a limiting nutrient (i.e., in short supply). Consequently, phosphorus is added to most agricultural fertilizers, which can cause environmental problems related to runoff in aquatic ecosystems.
44.3K
Glassware Calibration
1.5K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.5K
Line Loss
550
The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
550
Instrument Calibration
805
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
805
Reducing Line Loss
396
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
396
Chirality at Nitrogen, Phosphorus, and Sulfur
7.1K
Chirality is most prevalent in carbon-based tetrahedral compounds, but this important facet of molecular symmetry extends to sp3-hybridized nitrogen, phosphorus and sulfur centers, including trivalent molecules with lone pairs. Here, the lone pair behaves as a functional group in addition to the other three substituents to form an analogous tetrahedral center that can be chiral.
A consequence of chirality is the need for enantiomeric resolution. While this is theoretically possible for all...
A consequence of chirality is the need for enantiomeric resolution. While this is theoretically possible for all...
7.1K

