Aims:
The primary goal in the treatment of symptomatic atrial fibrillation/flutter (AF) is to restore sinus rhythm by cardioversion. Electrical shocks are highly effective, but have to be applied under analgo-sedation and can further harm the heart. In order to develop a novel pain-free and less harmful approach, we explored herein the optogenetic cardioversion by light-induced depolarization.
Methods And Results:
Hearts from mice expressing Channelrhodopsin-2 (ChR2) and the AF-promoting loss-of-function Connexin 40 Ala96Ser mutation were explanted and perfused with low K+ Tyrode's solution and an atrial KATP-channel activator. This new protocol shortened atrial refractoriness as well as slowed atrial conduction and thereby enabled the induction of sustained AF. AF episodes could be terminated by epicardial illumination of the atria with focussed blue light (470 nm, 0.4 mW/mm2) with an efficacy of ∼97% (n = 17 hearts). In > 80% of cases, light directly terminated the AF episode with onset of illumination. Because similar illumination intensity was able to locally inhibit atrial activity, we propose that a light-induced block of electrical activity is responsible for reliable AF termination. The success rate was strongly depending on the illuminated area, applied light intensity and duration of illumination. Importantly, we were also able to demonstrate optogenetic termination of AF in vivo, using epicardial illumination through the open chest (n = 3 hearts). To point towards a translational potential, we systemically injected an adeno-associated virus to express ChR2 in wild type hearts. After 6-8 months, we found robust ChR2 expression in the atria, enabling light-mediated AF termination in six of seven mice tested.
Conclusion:
We provide the first evidence for optogenetic termination of atrial tachyarrhythmia in intact hearts from transgenic as well as wild type mice ex and in vivo. Thus, this report could lay the foundation for the development of implantable devices for pain-free termination of AF.
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Termination of Translation
Termination of Translation
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Drag Force and Terminal Speed