Automated fraction of inspired oxygen (FiO2) control improves oxygen saturation targeting in preterm infants. This method significantly increases time within target SpO2 ranges and reduces harmful hyperoxia and hypoxia events.
Area of Science:
- Neonatal Medicine
- Respiratory Physiology
- Clinical Trial Methodology
Background:
- Maintaining optimal oxygen saturation (SpO2) in preterm infants is critical for neurodevelopment and reducing mortality.
- Manual control of fraction of inspired oxygen (FiO2) can lead to frequent fluctuations in SpO2, increasing risks of hyperoxia and hypoxia.
- Automated FiO2 control systems aim to provide more stable and precise oxygenation.
Purpose of the Study:
- To systematically review clinical trials comparing automated versus manual FiO2 control in preterm infants.
- To evaluate the efficacy of automated FiO2 control in achieving target SpO2 levels.
- To assess the impact of automated FiO2 control on reducing hyperoxic and hypoxic events.
Main Methods:
- Systematic review of randomized controlled trials identified through comprehensive database searches (MEDLINE, Embase, CENTRAL, CINAHL).
- Inclusion criteria focused on studies comparing automated FiO2 control with manual control in preterm infants receiving positive pressure respiratory support.
- Primary outcome was the percentage of time spent within the target SpO2 range; meta-analysis used random-effects models.
Main Results:
- Ten studies met inclusion criteria from 276 identified.
- Automated FiO2 control significantly increased the time spent within the target SpO2 range by 12.8% (95% CI: 6.5-19.2%).
- Automated control significantly reduced periods of hyperoxia (MD: -8.8%), severe hypoxia (SpO2 < 80%) (MD: -0.9%), and overall hypoxic events (MD: -5.6%).
Conclusions:
- Automated FiO2 adjustment is superior to manual control for optimizing oxygenation in preterm infants.
- This technology significantly improves time in target saturations, thereby reducing risks associated with abnormal oxygen levels.
- Automated FiO2 control represents a valuable advancement in respiratory support for vulnerable preterm neonates.
Objectives:
To conduct a systematic review of clinical trials comparing automated versus manual fraction of inspired oxygen (FiO2) control to target oxygen saturation (SpO2) in preterm infants.
Design:
The authors searched MEDLINE, Embase, CENTRAL, and CINAHL from inception upto December 2016, reviewed conference proceedings and sought results of unpublished trials. Studies were included if automated FiO2 control was compared to manual control in preterm infants on positive pressure respiratory support. The primary outcome was percentage of time spent within the target SpO2 range. Summary mean differences (MD) were computed using random effects model.
Results:
Out of 276 identified studies 10 met the inclusion criteria. Automated FiO2 control significantly improved time being spent within the target SpO2 range [MD: 12.8%; 95% CI: 6.5-19.2%; I2 = 90%]. Periods of hyperoxia (MD:-8.8%; 95% CI: -15 to -2.7%), severe hypoxia(SpO2 < 80%)(MD: -0.9%;95%CI: -1.5 to -0.4%) and hypoxic events (MD: -5.6%; 95% CI: -9.1 to -2.1%) were significantly reduced with automated control.
Conclusion:
Automated FiO2 adjustment provides significant improvement of time in target saturations, reduces periods of hyperoxia, and severe hypoxia in preterm infants on positive pressure respiratory support.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Transport in the Blood
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygenic Photosynthesis
Oxygen Requirements and Growth Patterns
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: