Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
Assessment of Corneal Biomechanical Properties with Inflation Test Using Optical Coherence Tomography
Like Wang1, Lei Tian2, Yanping Huang3,4
1Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China.
Abstract:
Biomechanical properties are important for the cornea to maintain its normal shape and function. There is still a need to develop better methods for accurate measurement of corneal mechanical properties. In this study, we propose to introduce the optical coherence tomography (OCT) in inflation test for the imaging of corneal deformation in order to measure its biomechanical properties. Ten cornea-mimicking silicone phantoms with different stiffness and five fresh porcine corneas were tested using the proposed method. Intra-ocular pressure was changed from 10 to 90 mmHg using two different loading rates to observe the pressure-apex displacement relationship and calculate the apparent stiffness of the corneas. Stiffness of the corneal phantoms obtained by the inflation test ranged from 0.2 to 1 MPa, which was highly consistent with the results from the mechanical tensile test (y = 0.70x, p < 0.001). The porcine corneas showed highly viscoelastic behavior with obvious hysteresis in inflation. The apparent stiffness of the porcine corneas was 0.63 ± 0.07 and 1.05 ± 0.08 MPa with loading rates of 3.3 and 33 mmHg/min, respectively. Mapping of corneal surface displacement was also generated for both the phantom and porcine corneas. This study showed that it is feasible to incorporate the high resolution OCT imaging in inflation test to measure the biomechanical properties of the cornea.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
07:44In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Related Concept Videos
Properties of Enantiomers and Optical Activity
Physical and Chemical Properties of Matter
Properties of Transition Metals
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
General Properties of Solutions
Convolution Properties I
The commutative property reveals that the input and the impulse response of an LTI (Linear Time-Invariant) system can be interchanged without affecting the output: