Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Structure of Cardiac Muscles01:13

Structure of Cardiac Muscles

17.4K
Cardiac muscle, or myocardium, is a specialized type of muscle found exclusively in the heart. Its unique structural and functional characteristics enable the heart to perform its vital role of pumping blood throughout the body continuously and rhythmically. The cardiac muscle cells, or cardiomyocytes, possess an endomysium and perimysium but do not have an epimysium.
Compared to skeletal muscles, cardiac muscle cells are small and mostly have a single nucleus. Additionally, they are usually...
17.4K
Sign Test for Matched Pairs01:17

Sign Test for Matched Pairs

434
The sign test for matched pairs offers a robust method for comparing two paired samples, often for the effects of an intervention in one of them. This method is very useful in situations where the underlying distribution of the data is unknown. The test compares two related samples—often pre- and post-treatment measurements on the same subjects—to determine if there are significant differences in their median values.
To conduct the sign test, we first calculate the differences in...
434
Trial and Error and Algorithm01:12

Trial and Error and Algorithm

435
A problem-solving strategy is a plan of action used to find a solution. Different strategies have distinct action plans. Trial and error involves trying different solutions until one works. For instance, to fix a broken printer, you might check ink levels, ensure the paper tray isn't jammed, and verify the printer's connection to your laptop. This method can be time-consuming but is commonly used. Thomas Edison, for example, used trial and error to find a suitable filament for the light...
435
What are Estimates?01:06

What are Estimates?

8.9K
It isn't easy to measure a parameter such as the mean height or the mean weight of a population. So, we draw samples from the population and calculate the mean height or mean weight of the individuals in the sample. This sample data acts as a representative measure of the population parameter. These sample statistics are known as estimates. 
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
8.9K
Wilcoxon Signed-Ranks Test for Matched Pairs01:09

Wilcoxon Signed-Ranks Test for Matched Pairs

508
The Wilcoxon signed-rank test for matched pairs evaluates the null hypothesis by combining the ranks of differences with their signs. It essentially tests whether the median of the differences in a population of matched pairs is zero. Since the test incorporates more information than the sign test, it generally yields more trustable conclusions. This test also does not require the data to follow a normal distribution, but two conditions must be met for it to be applicable: (1) the data must...
508
Estimation of k and VD of Aminoglycosides01:20

Estimation of k and VD of Aminoglycosides

256
Aminoglycosides are a class of antibiotics used to treat various bacterial infections. Clinicians must determine the elimination rate constant (k) and volume of distribution (VD) to optimize therapeutic efficacy and minimize toxicity. The k value represents the rate at which the drug is removed from the body, and the VD reflects the degree to which the drug distributes into body tissues. Accurately estimating these parameters allows healthcare professionals to tailor drug dosing to individual...
256

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Enhanced nitrogen and phosphorus removal from mining-affected waters by micro-nano aeration coupled with microbial remediation.

Environmental technology·2026
Same author

Comparative analysis of four nutritional scores in predicting hospital stay duration for EICU Patients with acute pancreatitis.

Frontiers in nutrition·2026
Same author

Spatial transcriptomics identifies distinct domains regulating yield-component traits of the wheat ear.

Science advances·2026
Same author

A TaKNOX1-TaAPO1-Rht1 feedback regulation orchestrates spikelet number and yield potential in wheat.

Plant communications·2026
Same author

In Situ Construction of Superhydrophobic Photothermal Coatings Based on Metal-Polyphenol Coordination Complex for Anti-/De-Icing Applications.

Polymers·2026
Same author

Dynamics of H3K4me3 and H3K36me3 histone modifications in response to powdery mildew infection in common wheat.

BMC plant biology·2026
Same journal

Classification of periapical radiographic findings for root canal therapy decision support using deep neural networks.

BMC medical informatics and decision making·2026
Same journal

Machine learning-based risk assessment of neonatal perinatal adverse outcomes of anemia during pregnancy: a modeling study.

BMC medical informatics and decision making·2026
Same journal

Intelligent differentiation between Parkinson's disease and essential tremor using wearable sensors and machine learning: a temporal validation study.

BMC medical informatics and decision making·2026
Same journal

Risk prediction of sepsis-associated acute kidney injury: development, validation of a machine learning model with multicenter data.

BMC medical informatics and decision making·2026
Same journal

Trajectory analysis of sleep disorders and anxiety-depression in female breast cancer patients undergoing chemotherapy: based on group-based Multi-Trajectory Model and machine learning.

BMC medical informatics and decision making·2026
Same journal

Multitask learning of longitudinal circulating biomarkers and clinical outcomes: identification of optimal machine-learning and deep-learning models.

BMC medical informatics and decision making·2026
See all related articles

Related Experiment Video

Updated: Feb 16, 2026

Estimating Vestibular Perceptual Thresholds Using a Six-Degree-Of-Freedom Motion Platform
06:31

Estimating Vestibular Perceptual Thresholds Using a Six-Degree-Of-Freedom Motion Platform

Published on: August 4, 2022

3.7K

Surface structure feature matching algorithm for cardiac motion estimation.

Zhengrui Zhang1, Xuan Yang2, Cong Tan3

  • 1College of Information Engineering, Shenzhen University, Shenzhen, 518060, China.

BMC Medical Informatics and Decision Making
|January 4, 2018
PubMed
Summary
This summary is machine-generated.

This study introduces a novel algorithm for estimating left ventricle (LV) motion in cardiac MR images by integrating surface structure features with point set matching. The method enhances registration accuracy and statistical robustness for improved cardiac disease diagnosis.

Keywords:
Gaussian mixture modelPoint set matchingStochastic gradient descentSurface structure feature

More Related Videos

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
08:10

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation

Published on: July 20, 2022

2.2K
Contrast-Matching Detergent in Small-Angle Neutron Scattering Experiments for Membrane Protein Structural Analysis and Ab Initio Modeling
10:27

Contrast-Matching Detergent in Small-Angle Neutron Scattering Experiments for Membrane Protein Structural Analysis and Ab Initio Modeling

Published on: October 21, 2018

13.1K

Related Experiment Videos

Last Updated: Feb 16, 2026

Estimating Vestibular Perceptual Thresholds Using a Six-Degree-Of-Freedom Motion Platform
06:31

Estimating Vestibular Perceptual Thresholds Using a Six-Degree-Of-Freedom Motion Platform

Published on: August 4, 2022

3.7K
Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
08:10

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation

Published on: July 20, 2022

2.2K
Contrast-Matching Detergent in Small-Angle Neutron Scattering Experiments for Membrane Protein Structural Analysis and Ab Initio Modeling
10:27

Contrast-Matching Detergent in Small-Angle Neutron Scattering Experiments for Membrane Protein Structural Analysis and Ab Initio Modeling

Published on: October 21, 2018

13.1K

Area of Science:

  • Medical Imaging
  • Computational Biology
  • Cardiovascular Research

Background:

  • Cardiac diseases are a leading cause of global mortality.
  • Left ventricle (LV) structural and functional changes are key indicators of cardiac disease progression.
  • Accurate LV motion estimation is crucial for diagnosing and managing cardiac conditions.

Purpose of the Study:

  • To develop an accurate algorithm for left ventricle (LV) motion estimation in cardiac cine magnetic resonance (MR) images.
  • To combine point set matching with myocardial surface structure features for enhanced motion estimation.
  • To improve the diagnosis and treatment of cardiac diseases through precise LV motion analysis.

Main Methods:

  • Describing myocardial wall structure using normal vector directions of contour points.
  • Employing Gaussian Mixture Models (GMMs) to represent LV structure and point set positions.
  • Defining a novel cost function comparing GMMs of structure features and point positions.
  • Optimizing the cost function using a hybrid approach combining Stochastic Gradient Descent (SGD) and Quasi-Newton (QN) methods.

Main Results:

  • The algorithm was validated on three public datasets, including cardiac MR image sequences from 33 subjects and 14 inter-subject heart cases.
  • The combined SGD and Quasi-Newton optimization demonstrated inherent statistical robustness.
  • The proposed method outperformed existing point set registration techniques in terms of registration accuracy.

Conclusions:

  • A novel and effective algorithm for cardiac motion estimation was developed by incorporating LV surface structure features into point set matching.
  • A new cost function effectively measures discrepancies between GMMs of point sets and their structure descriptors.
  • The algorithm exhibits improved registration accuracy and convergence in high-dimensional parameter spaces, offering a computationally efficient solution.