Study of helical flow inducers with different thread pitches and diameters in vena cava

Ying Chen1,2, Xiaoyan Deng1,2, Xinying Shan1,2

  • 1Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.

Plos One
|January 4, 2018
PubMed

Related Concept Videos

Perceiving Loudness, Pitch, and Location01:21

Perceiving Loudness, Pitch, and Location

The human brain perceives pitch through two primary mechanisms reflected in place theory and frequency theory. Each mechanism describes how sound waves are interpreted as specific pitches by the brain, offering insights into the intricate processes of auditory perception.
Place theory, or place coding, suggests that different pitches are heard because various sound waves activate specific locations along the cochlea's basilar membrane. The brain determines the pitch of a sound by...
1.0K
Design Example: Calculating Safe Diameter for Wind-Exposed Disc01:17

Design Example: Calculating Safe Diameter for Wind-Exposed Disc

Assessing safety in wind-exposed installations is crucial to preventing potential failures. This example explores the calculation and design adjustments needed to mount a circular disc on a building facade, where wind forces are a primary concern. A 4-meter diameter disc was initially designed as an aesthetic feature facing winds at a velocity of 25 meters per second, with an air density of 1.25 kilograms per cubic meter. Given these conditions, the drag force on the disc was determined using...
365
Gene Flow02:39

Gene Flow

Gene flow is the transfer of genes among populations, resulting from either the dispersal of gametes or from the migration of individuals.
38.1K
Flow Cytometry01:23

Flow Cytometry

The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
16.5K
Flow Sheet01:17

Flow Sheet

Flowsheets are valuable tools in nursing documentation. They enable healthcare professionals to efficiently record and monitor various patient assessments and measurements in a consolidated format.
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation:
2.9K
Flow Table Test01:12

Flow Table Test

The flow table test is an established method used to assess the workability of concrete, particularly useful for evaluating highly flowable concrete mixes. This test employs an apparatus that consists of a wooden board topped with a steel plate, collectively weighing 35 pounds. The board is connected to a base via a hinge and measures 27.6 inches on each side.
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
779