Related Experiment Video
Updated: Feb 16, 2026

Intrauterine Telemetry to Measure Mouse Contractile Pressure In Vivo
Published on: April 6, 2015
Bleeding pattern difference between levonorgestrel intrauterine system and copper intrauterine devices inserted
Xiaoning Chen1, Qianxi Li2, Xiaoye Wang3
1a Family Planning Department , Jiangxi Maternal and Child Health hospital , Nanchang , China.
Background:
To describe the bleeding pattern (primary outcome), side effects, treatment satisfaction and 6 month continuity rates associated with the 52 mg levonorgestrel intrauterine system (LNG-IUS) and the copper intrauterine device (Cu-IUD) inserted immediately after abortion.
Methods:
This multicenter, prospective, observational cohort study enrolled healthy women (aged ≥18 years) inserted with LNG-IUS or Cu-IUD immediately after first-trimester surgical abortion and followed up to 6 months. Bleeding pattern was obtained through daily patient bleeding diaries.
Results:
From 2013 to 2014, we enrolled 512 women (LNG-IUS = 312 [median age: 32.0 years] and Cu-IUD = 200 [median age: 30.0 years]) from nine Chinese centers. LNG-IUS resulted in a significantly lower number of bleeding/spotting days in the second 90 day reference period compared with Cu-IUD (median 14.5 vs. 18.0 days, p < .0001). Amenorrhea rate (no bleeding/spotting day in the second 90 day reference period) and no menstrual bleeding rate (absence of bleeding days in the second 90 day reference period) were significantly higher in LNG-IUS compared to Cu-IUD (13.9% vs. 0% and 39.5% vs. 0%; p < .001 for all). No dysmenorrhea was higher at the last follow-up in LNG-IUS users than Cu-IUD users (81.2% vs. 76%; p = .0047). Both treatments had a high satisfaction rate among women at both the follow-up visits, and the majority of them continued with the treatment. The rates of adverse events (e.g. oligomenorrhea, amenorrhea) in the LNG-IUS and Cu-IUD groups were 77.2% and 44.5% (p < .0001), respectively.
Conclusion:
LNG-IUS post-abortion shows better bleeding patterns, and reduced dysmenorrhea and bleeding amount, but with a similar safety profile compared with Cu-IUD. ClinicalTrials.gov identifier: NCT01958684.
Related Concept Videos
Intrauterine Drug Delivery Systems
Observational Studies
There are three types of observational studies – Prospective, retrospective, and cross-sectional.
Prospective Study
Prospective studies, also known as longitudinal or cohort studies, are carried out by collecting future data from groups sharing similar characteristics. One...
Bleeding in Fresh Concrete
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
Naturalistic Observations
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...

