Substernal Thyroid Biopsy Using Endobronchial Ultrasound-guided Transbronchial Needle Aspiration
Published on: November 10, 2014
Contrast enhanced ultrasound guided biopsies of liver lesions not visualized on standard B-mode
Sasan Partovi1, Ziang Lu2, Rivka Kessner1
1Department of Radiology, University Hospitals Cleveland Medical Center, Case Western Reserve University, Cleveland, Ohio, USA.
Background:
To assess the technical success of contrast enhanced ultrasound (CEUS) guided biopsies of liver lesions poorly visualized on B-mode ultrasound.
Methods:
Patients were selected during the procedure based on the real-time clinical scenario of unsatisfactory B-mode ultrasound lesion visualization and all patients would have otherwise undergone CT guided liver lesion biopsy. A total of 26 patients underwent CEUS guided biopsy and were included in this retrospective analysis. The review of the patients' files included demographic information, lesion characteristics on imaging, procedural details and pathology outcome. Technical success was defined as concordance between the radiological findings, pathology report and clinical follow-up-demonstrating lack of need for re-biopsy or re-biopsy with identical pathological results. Patients with less than 2 months follow-up were excluded from the study.
Results:
CEUS guided liver biopsy was successful in 23 out of 26 patients (88.5%). The average procedure time was 30.7±12.3 minutes and the average lesion size was 2.2±1.7 cm. The majority of lesions (80.8%) were hypoenhancing on the delayed phase of CEUS. The mean number of samples taken from each lesion per procedure was 3.2 (±1.7).
Conclusions:
CEUS guidance biopsies of focal liver lesions (FLL) that were difficult to visualize on B-mode ultrasound demonstrated high success rate and may be an evolving image guidance modality in selected patients to avoid CT guided procedures.
More Related Videos
06:08A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
07:44Endoscopic Ultrasound-Guided Biliary Drainage: Endoscopic Ultrasound-Guided Hepaticogastrostomy in Malignant Biliary Obstruction
Published on: March 25, 2022
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
MOSFET: Enhancement Mode
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...