Background:
The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higher rate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of these fractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal end clavicle fractures treated with superior anterior locking plate.
Methods:
From June 2011 to August 2015 a retrospective study of12 male patients (mean age of 41.3 years) 11 with unilateral and 1 with bilateral distal clavicle fractures treated with superior anterior locking plate was done. They were evaluated at regular intervals with mean follow up of 14 months(12-18 months). Those with minimum one year follow up were included in our study. All were evaluated for the functioning of the shoulder joint by both Oxford shoulder score and Quick DASH scores, rate of bone union, complications and earliest time for return to work.
Results:
All fractures union seen within 6-8 weeks (mean time: 7.1 weeks). All had good shoulder range of motion. The average oxford shoulder and Quick DASH score were 46.2 and 6.5. There were no major complications in our study viz. non-union, plate failure, secondary fracture. But one patient had superficial wound infection. All patients returned to work within 3 months of postoperative period.
Conclusion:
Displaced distal clavicle fractures treated with superior anterior locking plates achieved excellent results in terms of bony union with rarely any complications and demonstrate promising results with this novel technique.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
05:18Collection of Skeletal Muscle Biopsies from the Superior Compartment of Human Musculus Tibialis Anterior for Mechanical Evaluation
Published on: September 27, 2020
Related Concept Videos
Types of Functions I
Types of Functions II
Types of Functions III
T Cell Types and Functions
Th1 cells stimulate dendritic cells to express necessary co-stimulatory molecules on their surfaces for...
Diabetes Mellitus: Type 2 and Gestational
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.