Related Experiment Video
Updated: Feb 16, 2026

Assessment of DNase Activity by Ratiometric Fluorescence Resonance Energy Transfer
Published on: July 25, 2025
Hairpin-Contained i-Motif Based Fluorescent Ratiometric Probe for High-Resolution and Sensitive Response of Small pH
Wenjie Ma1, Lv'an Yan1, Xiaoxiao He1
1State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Biology, College of Chemistry and Chemical Engineering, Hunan University, Key Laboratory for Bio-Nanotechnology and Molecule Engineering of Hunan Province , Changsha 410082, China.
Abstract:
Intracellular pH (pHi) is an important parameter associated with cellular behaviors and pathological conditions. Sensing pHi and monitoring its changes are essential but challenging due to the lack of high-sensitive probes. Herein, a ratiometric fluorescent probe with ultra pH-sensitivity is developed based on hairpin-contained i-motif strand (I-strand, labeled with Rhodamine Green and BHQ2 at two termini) and complementary strand (C-strand, labeled with Rhodamine Red at its 5'-end). At neutral pH, both I-strand and C-strand hybridize into a rigid duplex (I-C), which holds the Rhodamine Red and the BHQ2 in close proximity. As a result, the fluorescence emission (F597 nm) of the Rhodamine Red is strongly suppressed, while the Rhodamine Green (F542 nm) is in a "signal on" state. However, the slightly acidic pH enforced the I-strand to form an intramolecular i-motif and initiated the dehybridization of I-C duplex, leading to Rhodamine Red in a "signal on" state and a decreased fluorescence of Rhodamine Green. The ratio (F542 nm/F597 nm) can be used as a signal for pH sensing. Due to the rational internal hairpin design of I-C duplex probe, almost 70-fold change in the ratio was observed in the physiological pH range (6.50-7.40). This probe possesses efficient stability, fast response, and reversible pH measurement capabilities. Furthermore, intracellular application of the ratiometric probe was demonstrated on the example of SMMC-7721 cells. With different recognition elements in engineering of i-motif based platforms, the design might hold great potential to become a versatile strategy for intracellular pH sensing.
Related Concept Videos
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Super-resolution Fluorescence Microscopy
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...

