Short cervix in twin pregnancies: current state of knowledge and the proposed scheme of treatment

Hubert Huras1, Jarosław Kalinka, Romuald Dębski

  • 1Department of Obstetrics and Perinatology, Jagiellonian University Medical College in Kraków, Mikołaja Kopernika St. 23, 31-501 Kraków, Poland. huberthuras@wp.pl.

Ginekologia Polska
|January 6, 2018
PubMed

Short cervical length (SCL) should be defined as cervical length (CL) less than 25 mm between 18 and 22 weeks of gestation. This definition of SCL is fully applicable for singleton pregnancies but is not entirely correct for twin pregnancies. So far there are no explicit guidelines on the treatment of twin pregnancy with SCL. The use of progesterone in the treatment of SCL and preterm birth (PTB) prophylaxis is one of the interventions recommended by the Polish Ministry of Health for cervical shortening in singleton pregnancies. In twin pregnancies attention should be paid to the potential benefits of using vaginal progesterone in reduction of neonatal mortality and incidence of neonatal complications in a group of patients with twin pregnancies and CL less than 25 mm or below the 10th percentile for the gestational age, measured between 18 and 22 weeks of gestation. It is still difficult to identify the benefits of using pessaries in the prevention of PTB in twin pregnancies. The usage of pessaries appears to be beneficial only in selected subpopulations of patients with asymptomatic CL less than 25 mm or 10th percentile for gestational age. The use of cervical cerclage in PTB prevention in twin pregnancies is limited to cases where the external cervical dilation is >1 cm and.

Related Concept Videos

Uterus and Cervix01:18

Uterus and Cervix

The uterus, commonly called the womb, is a vital reproductive organ in females designed to provide a nurturing environment for the implantation and growth of an embryo. It is shaped like a hollow pear and positioned between the urinary bladder and the rectum. The uterus's structure allows it to support and protect a developing fetus throughout pregnancy.
The uterus is securely anchored within the pelvic cavity by paired broad ligaments on either side. It is further stabilized by three pairs...
5.6K
The Z-Scheme of Electron Transport in Photosynthesis01:34

The Z-Scheme of Electron Transport in Photosynthesis

The light reactions of photosynthesis assume a linear flow of electrons from water to NADP+. During this process, light energy drives the splitting of water molecules to produce oxygen. However, oxidation of water molecules is a thermodynamically unfavorable reaction and requires a strong oxidizing agent. This is accomplished by the first product of light reactions: oxidized P680 (or P680+), the most powerful oxidizing agent known in biology. The oxidized P680 that acquires an electron from the...
13.9K
Electrical Current01:10

Electrical Current

Electrical current is defined as the rate at which charge flows. When there is a large current present, such as that used to run a refrigerator, a large amount of charge moves through the wire in a small amount of time. If the current is small, such as that used to operate a handheld calculator, a small amount of charge moves through the circuit over a long period of time. The SI unit for current is the ampere (A), named for the French physicist André-Marie Ampère (1775–1836).
7.2K
Short-distance Transport of Resources02:12

Short-distance Transport of Resources

Short-distance transport refers to transport that occurs over a distance of just 2-3 cells, crossing the plasma membrane in the process. Small uncharged molecules, such as oxygen, carbon dioxide, and water, can diffuse across the plasma membrane on their own. In contrast, ions and larger molecules require the assistance of transport proteins due to their charge or size. Transport across membranes also occurs within individual cells, playing a variety of essential roles for the plant as a whole.
17.8K
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
578
Current Density01:21

Current Density

The total amount of current flowing through one unit value of a cross-sectional area is referred to as current density. If the current flow is uniform, the amount of current flowing through a conductor is the same at all points along the conductor, even if the conductor area varies. The current density consists of the local magnitude and direction of the charge flow, which varies from point to point. Current density is measured in amperes per meter square, and direction is defined as the net...
5.2K