Related Experiment Video
Updated: Feb 16, 2026

Designing CAD/CAM Surgical Guides for Maxillary Reconstruction Using an In-house Approach
Published on: August 24, 2018
Prosthetically CAD-CAM-Guided Bone Augmentation of Atrophic Jaws Using Customized Titanium Mesh: Preliminary Results
Leonardo Ciocca1, Giuseppe Lizio2, Paolo Baldissara1
11 Section of Prosthodontics, Department of Biomedical and Neuromotor Science, Alma Mater Studiorum, University of Bologna, Bologna, Italy.
Abstract:
This study evaluated the outcomes of computer-aided design-computer-aided machining (CAD-CAM)-customized titanium mesh used for prosthetically guided bone augmentation related to the occlusion-driven implant position, to the vertical bone volume gain of the mandible and maxilla, and to complications, such as mesh exposure. Nine patients scheduled for bone augmentation of atrophic sites were treated with custom titanium mesh and particulate bone grafts with autologous bone and anorganic bovine bone in a 1:1 ratio prior to implant surgery. The bone volume needed to augment was virtually projected based on implant position, width, and length, and the mesh design was programmed for the necessary retaining screws. After 6 to 8 months, bone augmentations of 1.72 to 4.1 mm (mean: 3.83 mm) for the mandibular arch and 2.14 to 6.88 mm (mean: 3.95 mm) for the maxilla were registered on cone-beam computerized tomography. Mesh premature (within 4 to 6 weeks) exposure was observed in 3 cases and delayed (after 4 to 6 weeks) in 3 other cases. One titanium mesh was removed before the programmed time but in all augmented sites was possible implant insertion. No complication occurred during prosthetic follow-up. Using CAD-CAM technology for prosthetically guided bone augmentation showed important postoperative morbidity of mesh exposure (66%). Because of this high prevalence of mesh exposure and the potential infection that could affect the expected bone augmentation, this study suggests a cautious approach to this procedure when designing the titanium mesh, to avoid flap tension that may cause mucosal rupture.
Related Concept Videos
C4 Pathway and CAM
C4 Pathway
The C4 pathway is used by plants such as...
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Bone Structure
Bone Remodeling

