Related Experiment Video
Updated: Feb 16, 2026

Retzius-Sparing Robot-Assisted Radical Prostatectomy
Published on: May 19, 2022
Effect of pressure-controlled inverse ratio ventilation on dead space during robot-assisted laparoscopic radical
Go Hirabayashi1, Yukihiko Ogihara, Shoichi Tsukakoshi
1From the Mizonokuchi Hospital, Teikyo University School of Medicine, Kanagawa (GH, KM, TA), Department of Anaesthesiology, Tokyo Medical University (YO), Department of R&D, Senko Medical Instrument Co., Ltd. (ST), Furrex Co., Ltd., Tokyo, Japan (KD), S.K.I. Net, Inc., Tokyo (MI), and Department of Anesthesiology and Intensive Care Medicine, International University of Health and Welfare, School of Medicine, Narita, Japan (KK).
Background:
Pressure-controlled inverse inspiratory to expiratory ratio ventilation (PC-IRV) is thought to be beneficial for reducing the dead space volume.
Objective:
To investigate the effects of PC-IRV on the components of dead space during robot-assisted laparoscopic radical prostatectomy (RLRP).
Design:
A randomised crossover study of three different ventilator modes.
Setting:
A single university hospital from September 2014 to April 2015.
Patients:
Twenty consecutive study participants undergoing RLRP.
Interventions:
Patients were ventilated sequentially with three different modes in random order for 30 min: volume control ventilation (VCV; inspiratory to expiratory ratio 0.5), pressure control ventilation (PCV; inspiratory to expiratory ratio 0.5) and PC-IRV. Inverse inspiratory to expiratory ratio was adjusted individually by observing the expiratory flow-time wave to prevent the risk of dynamic pulmonary hyperinflation.
Main Outcome Measures:
The primary outcome included physiological dead space (VDphys), airway dead space (VDaw), alveolar dead space (VDalv) and shunt dead space (VDshunt). VDphys was calculated by Enghoff's method. We also analysed respiratory dead space (VDresp) and VDaw using a novel analytical method. Then, VDalv and VDshunt were calculated by VDalv = VDresp - VDaw and VDshunt = VDphys - VDresp, respectively.
Results:
The VDphys/expired tidal volume (VTE) ratio in PC-IRV (29.2 ± 4.7%) was significantly reduced compared with that in VCV (43 ± 8.5%) and in PCV (35.9 ± 3.9%). The VDshunt/VTE in PC-IRV was significantly smaller than that in VCV and PCV. VDaw/VTE in PC-IRV was also significantly smaller than that in VCV but not that in PCV. There was no significant change in VDalv/VTE.
Conclusion:
PC-IRV with the inspiratory to expiratory ratio individually adjusted by the expiratory flow-time wave decreased VDphys/VTE in patients undergoing RLRP.
Trial Registration:
University Hospital Medical Information Network in Japan 000014004.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation I: Indication and Settings