Related Experiment Video
Updated: Feb 16, 2026

Green Fluorescent Protein-based Expression Screening of Membrane Proteins in Escherichia coli
Published on: January 6, 2015
Development of a biosensor protein bullet as a fluorescent method for fast detection of Escherichia coli in drinking
Ignacio Gutiérrez-Del-Río1, Laura Marín1, Javier Fernández1
1Research Group BIONUC, Departamento de Biología Funcional, Área de Microbiología, University of Oviedo, Oviedo, Principality of Asturias, Spain.
Abstract:
Drinking water can be exposed to different biological contaminants from the source, through the pipelines, until reaching the final consumer or industry. Some of these are pathogenic bacteria and viruses which may cause important gastrointestinal or systemic diseases. The microbiological quality of drinking water relies mainly in monitoring three indicator bacteria of faecal origin, Escherichia coli, Enterococcus faecalis and Clostridium perfringens, which serve as early sentinels of potential health hazards for the population. Here we describe the analysis of three chimeric fluorescent protein bullets as biosensor candidates for fast detection of E. coli in drinking water. Two of the chimeric proteins (based on GFP-hadrurin and GFP-pb5 chimera proteins) failed with respect to specificity and/or sensitivity, but the GFP-colS4 chimera protein was able to carry out specific detection of E. coli in drinking water samples in a procedure encompassing about 8 min for final result and this biosensor protein was able to detect in a linear way between 20 and 103 CFU of this bacterium. Below 20 CFU, the system cannot differentiate presence or absence of the target bacterium. The fluorescence in this biosensor system is provided by the GFP subunit of the chimeric protein, which, in the case of the better performing sensor bullet, GFP-colS4 chimera, is covalently bound to a flexible peptide bridge and to a bacteriocin binding specifically to E. coli cells. Once bound to the target bacteria, the excitation step with 395 nm LED light causes emission of fluorescence from the GFP domain, which is amplified in a photomultiplier tube, and finally this signal is converted into an output voltage which can be associated with a CFU value and these data distributed along mobile phone networks, for example. This method, and the portable fluorimeter which has been developed for it, may contribute to reduce the analysis time for detecting E. coli presence in drinking water.
Related Concept Videos
Development of Analytical Methods
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Fast Fourier Transform
The computational efficiency of the FFT becomes...
Chemotaxis in E. coli
The Water Cycle

