Related Experiment Video
Updated: Feb 16, 2026

Determination of the Glycogen Content in Cyanobacteria
Published on: July 17, 2017
Detection of Cyanobacteria in Eutrophic Water Using a Portable Electrocoagulator and NanoGene Assay
Eun-Hee Lee1, Beelee Chua2, Ahjeong Son1
1Department of Environmental Science and Engineering, Ewha Womans University , Seoul, Republic of Korea.
Abstract:
We have demonstrated the detection of cyanobacteria in eutrophic water samples using a portable electrocoagulator and NanoGene assay. The electrocoagulator is designed to preconcentrate cyanobacteria from water samples prior to analysis via NanoGene assay. Using Microcystis aeruginosa laboratory culture and environmental samples (cell densities ranging from 1.7 × 105 to 4.1 × 106 and 6.5 × 103 to 6.6 × 107 cells·mL-1, respectively), the electrocoagulator was evaluated and compared with a conventional centrifuge. Varying the operation duration from 0 to 300 s with different cell densities was first investigated. Preconcentration efficiencies (obtained via absorbance measurement) and dry cell weight of preconcentrated cyanobacteria were then obtained and compared. For laboratory samples at cell densities from 3.2 × 105 to 4.1 × 106 cells·mL-1, the preconcentration efficiencies of electrocoagulator appeared to be stable at ∼60%. At lower cell densities (1.7 and 2.2 × 105 cells·mL-1), the preconcentration efficiencies decreased to 33.9 ± 0.2 and 40.4 ± 5.4%, respectively. For environmental samples at cell densities of 2.7 × 105 and 6.6 × 107 cells·mL-1, the electrocoagulator maintained its preconcentration efficiency at ∼60%. On the other hand, the centrifuge's preconcentration efficiencies decreased to nondetectable and below 40%, respectively. This shows that the electrocoagulator outperformed the centrifuge when using eutrophic water samples. Finally, the compatibility of the electrocoagulator with the NanoGene assay was verified via the successful detection of the microcystin synthetase D (mcyD) gene in environmental samples. The viability of the electrocoagulator as an in situ compatible alternative to the centrifuge is also discussed.
Related Concept Videos
Bacterial Phylum Cyanobacteria
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
The Water Cycle
Water and Mineral Acquisition
Quality of Water
Regulation of Water Intake

