Related Experiment Video
Updated: Feb 16, 2026

Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Anterolateral distal tibia locking plate osteosynthesis and their ability to capture OTAC3 pilon fragments
Arun Aneja1, T David Luo2, Boshen Liu1
1Department of Orthopaedic Surgery and Sports Medicine, University of Kentucky, Lexington, KY 40536, USA.
Background:
Intra-articular Pilon fractures remain therapeutically challenging due to osteochondral fracturing and comminution, marginal impaction, and insult to the soft tissue envelope. The purpose of this study was to compare the efficacy of anterolateral distal tibial locking plates in capturing main fracture fragments in tibial plafond fractures.
Methods:
From May 2011 to Dec 2015, 169 OTA C-type pilon fractures met inclusion and exclusion criteria with computed tomographic (CT) scans performed prior to definitive fixation. For each patient, the fracture lines were mapped, digitized, and graphically superimposed to create a compilation of fracture lines. Based on these average measurements, three distal tibia sawbones had three different anterolateral plates applied. Axial CT scan images were used to determine the efficacy of screw purchase in main fracture fragments in pilon fractures.
Results:
The Smith & Nephew PERI-LOC plate secured the largest number of fracture lines (90.1%) but missed the Volkmann fragment with greatest frequency at 3.6%. The Synthes 2.7/3.5 mm VA-LCP captured 87.3% of the fracture lines while missing the Volkmann fragment 3.2% of the time. The Synthes 3.5 mm LCP captured 86.5% of the fracture lines but was the best at securing the Volkmann fragment (1.2% missed). All three implants were deficient in capturing the medial malleolar fragment. The PERI-LOC and 2.7/3.5 mm VA-LCP did not differ with respect to percentage of fragments captured (p = 0.721) but both outperformed the 3.5 mm LCP (p = 0.021 and p = 0.05, respectively).
Conclusions:
This study was consistent with prior literature in defining three main fracture fragments: anterior, medial, and posterior. All three plates were deficient in capturing the medial malleolar fragment. The Smith and Nephew PERI-LOC plate secured the most number of fracture lines, while the Synthes 3.5 mm LCP was least likely to miss the Volkmann fragment and most likely to miss the medial malleolar fragment. No plate was found to be superior to the other in capturing all fracture lines of the OTAC3 pilon fragments.
Level Of Evidence:
Three.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Habitat Fragmentation
Bones of the Lower Limb: Tibia and Fibula
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Mass Spectrometry: Alkene Fragmentation
Mass Spectrometry: Amine Fragmentation
In amines, the number of nitrogen atoms affects the mass of the molecular ion, which is described by the nitrogen rule of mass spectrometry. This rule states that a compound containing a single...
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...