Related Experiment Video
Updated: Feb 16, 2026

Swab Sampling Method for the Detection of Human Norovirus on Surfaces
Published on: February 6, 2017
Evaluation of Simplexa Group A Strep Direct Kit Compared to Hologic Group A Streptococcal Direct Assay for Detection
Deirdre L Church1,2,3, Tracie Lloyd4, Oscar Larios4,2,3
1Division of Microbiology, Calgary Laboratory Services, University of Calgary, Calgary, Alberta, Canada Deirdre.church@cls.ab.ca.
Abstract:
Diagnosis of bacterial pharyngitis is confirmed by detection of group A Streptococcus (GAS) in patient throat samples. Testing of throat samples has historically relied on culture, but new molecular methods allow much faster test turnaround time (i.e., same day versus 48 to 72 h for culture). Our laboratory uses the Hologic GAS Direct (GASD) assay for screening more than 125,000 throat samples per year. Simplexa GAS Direct is a new real-time quantitative PCR (qPCR) assay that does not require initial DNA extraction. Performance of Simplexa qPCR was compared to GASD. A total of 289 throat swabs were collected from patients attending ambulatory clinics in Calgary, Alberta, Canada. A total of 60 (20.8%) of the samples were initially GAS positive by either method: 54 by both methods, 4 by Simplex qPCR alone, and 2 by GASD alone. An in-house PCR using a unique GAS primer set was used to resolve the 6 discrepant results. Overall, GASD compared to Simplexa qPCR had a sensitivity, specificity, positive predictive value, and negative predictive value of 93.1% versus 100%, 100% versus 100%, 100% versus 100%, and 98.31% versus 100%, respectively. Implementation of Simplexa qPCR in our laboratory setting would cost more but allow the high sample volume to be reported in half the time and save 0.62 medical laboratory technician (MLT) full-time equivalent (FTE). In comparison to culture, the implementation of Simplexa qPCR would save 2.79 medical laboratory assistant (MLA) FTE plus 0.94 MLT FTE. Simplexa qPCR has improved performance and diagnostic efficiency in a high-volume laboratory compared to GASD for GAS detection in throat swabs.
Related Concept Videos
Evaluating Limits by Direct Substitution
Directing Effect of Substituents: meta-Directing Groups
Directing Effect of Substituents: ortho–para-Directing Groups
Directional Terms
Directional Relays
Direct Motor Pathways
The corticospinal tract is responsible for the voluntary movement of the limbs and trunk. It originates in the cerebral cortex of the brain and descends through the cerebrum's internal capsule and...

