Related Experiment Video
Updated: Feb 16, 2026

Optimization of In vitro Transcription Reaction for mRNA Production Using Chromatographic At-Line Monitoring
Published on: April 4, 2025
A mixed-mode chromatographic separation method for the analysis of dialkyl phosphates
Shaogang Chu1, Robert J Letcher1
1Ecotoxicology and Wildlife Health Division, Environment and Climate Change Canada, National Wildlife Research Centre, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario, K1A 0H3, Canada.
Abstract:
While reversed-phase (RP) liquid chromatography can separate a wide range of analytes, for strongly acidic compounds such as environmentally relevant dialkyl phosphates (DAPs), this remains a challenge because they have low affinity for standard RP columns or they exhibit inferior peak shapes. Mixed-mode chromatographic (MMC) columns, which contain both RP and ion-exchange functionalities, can address these resolution problems. However, using current MMC separation approaches, analyte peaks are relatively broad as compared to conventional RP chromatography. Herein we present an enhanced MMC-based UHPLC/ESI-MS method for the analysis of DAPs. In contrast to commonly available MMC-based methods, we applied the MMC Luna® Omega PS C18 column that was conditioned by 0.1% formic acid and equilibrated with the initial mobile phase before sample injection. This conditioning step tremendously improved the retention and separation of the DAPs, especially for those with high water solubility and shorter carbon chain lengths. Using water/methanol (95 v/5 v) and ammonium acetate in methanol as the mobile phases, nine DAPs could be baseline resolved with very sharp peaks, including the shorter-chain dimethyl phosphate, diethyl phosphate and bis(2-chloroethyl) phosphate. Other columns were examined to facilitate method optimization, and to identify stationary phases with the ability to separate DAPs as well as to elucidate the retention and separation mechanisms. With this novel UHPLC and post-column dication ion-pairing ESI-MS/MS method, instrumental detection limits as low as 0.01 ng/mL level were achieved. Representing other strongly acidic analytes, the short-chain perfluoroalkyl acid, perfluorobutyl sulfonic acid could also be analyzed with this method.
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Phosphate Buffer
Sodium dihydrogen phosphate does not fully dissociate in neutral or acidic solutions. When a strong base, such as sodium hydroxide (NaOH), is introduced into the solution, sodium dihydrogen phosphate...