Related Experiment Video
Updated: Feb 16, 2026

Spectrophotometric Determination of Phycobiliprotein Content in Cyanobacterium Synechocystis
Published on: September 11, 2018
Exploiting multivariate calibration for compensation of iron interference in the spectrophotometric flow-based
Eliezer Oliveira1, Camelia Henriquez1, Lidiane C Nunes1
1Centre for Nuclear Energy in Agriculture, University of Sao Paulo, Piracicaba, SP, Brazil.
Abstract:
Multivariate calibration involving partial least squares was exploited in the flow-based spectrophotometric determination of molybdenum in river waters relying on the Mo(VI)-catalyzed iodide oxidation by H2O2 under acidic conditions. Two sample aliquots were simultaneously inserted into the carrier stream, and differential pumping was accountable for in-line addition of sulfuric acid to one of them. Pronounced gradients (acidity and reagent concentrations) were established along the complex sample zone formed, and the absorbance-time function was characterized by local maximum and minimum values. As these values were intrinsically more precise, they were used for implementing the PLS multivariate calibration. Mo(VI) and Fe(III) were jointly determined, and Fe(III) interference was straightforwardly circumvented. Influence of reagent concentrations, acidity, available time for reaction development, and nature of the acid was investigated, and this later parameter manifested itself as relevant for discriminating purposes. The calibration set consisted of 6.2 - 50.0μgL-1 Mo(VI) plus 0.5 - 7.0mgL-1 Fe(III) solutions. The PLS model was characterized by good prediction ability [RMSEP = 0.67μgL-1 for Mo(VI)]. The innovation was applied to spiked river waters, and analytical precision, sampling rate, recovery, detection limit and reagent consumption were estimated as 0.5 - 2.4%, 31h-1, 98-114%. 0.88μgL-1 Mo(VI), and 54.0mg KI per determination, respectively. Results were in agreement with ICP OES.
Related Concept Videos
Dosage Compensation
In addition to sexual development, the X chromosome has genes involved in autosomal functions such as brain development and the immune system. Therefore, males and females with distinct numbers of X chromosomes will...
Compensation Mechanisms
Respiratory Compensation
This mechanism addresses metabolic-induced pH imbalances by adjusting breathing rates. Respiratory compensation begins within minutes of detecting a pH...
Interference and Diffraction
RNA Interference
This process occurs naturally in cells, often through the activity of genomically-encoded microRNAs. Researchers can take advantage of this mechanism by introducing synthetic RNAs to deactivate specific genes for research or therapeutic purposes. For example, RNAi could be used...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration