Related Experiment Video
Updated: Feb 16, 2026

Immunoglobulin Gene Sequence Analysis In Chronic Lymphocytic Leukemia: From Patient Material To Sequence Interpretation
Published on: November 26, 2018
A new approach for diagnosing chronic myelomonocytic leukemia using structural parameters of Sysmex XNTM analyzers in
Françoise Schillinger1, Elise Sourdeau2, Marouane Boubaya3
1a Laboratoire d'hématologie , Etablissement Français du Sang de Bourgogne/Franche-Comté , Besançon , France.
Abstract:
According to WHO recommendations, diagnosis of chronic myelomonocytic leukemia (CMML) beforehand requires microscopic examination of peripheral blood to identify dysplasia and/or blasts when monocytes are greater or equal to 1.0 × 109/L and 10% of leucocytes. We analyzed parameters derived from SysmexTM XN analyzers to improve the management of microscopic examination for monocytosis. We analyzed results of the complete blood count and the positioning and dispersion parameters of polymorphonuclear neutrophils and monocytes in 61 patients presenting with CMML and 635 control patients presenting with a reactive monocytosis. We used logistic regression and multivariate analysis to define a score for smear review. Three parameters were selected: neutrophil/monocyte ratio, structural neutrophil dispersion (Ne-WX) and monocyte absolute value. We established an equation in which the threshold of 0.160 guided microscopic examination in the search for CMML abnormalities with a sensitivity of 0.967 and a specificity of 0.978 in the learning cohort (696 samples) and 0.923 and 0.936 in the validation cohort (1809 samples) respectively. We created a score for microscopic smear examination of patients presenting with a monocytosis greater or equal to 1.0 × 109/L and 10% of leucocytes, improving efficiency in laboratory routine practice.
Related Concept Videos
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Wave Parameters
Characteristics of Practical Op Amps
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Theoretical Foundations of Nursing Practice
Theories provide a perspective to assess patients' conditions and organize data and methods. They also assist in analyzing and interpreting information. They represent a...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...

