Related Experiment Video
Updated: Feb 15, 2026

Viral Concentration Determination Through Plaque Assays: Using Traditional and Novel Overlay Systems
Published on: November 4, 2014
Comparison of five specific assays for determination of dabigatran plasma concentrations in patients enrolled in the
1Department of Angiology and Blood Coagulation, S. Orsola-Malpighi University Hospital, Bologna, Italy.
Introduction:
Several specific assays are commercially available to determine dabigatran anticoagulant activity. Aims of this multicenter and multiplatform study were to compare five methods for dabigatran measurement and investigate their performances in the low concentration range.
Methods:
Dabigatran levels were analyzed in 295 plasma samples from patients enrolled in the START-Laboratory Register by the following methods using dedicated calibrators and controls: STA-ECA II (Diagnostica Stago), standard and low range Hemoclot Thrombin Inhibitors (Hyphen BioMed), Direct Thrombin Inhibitor Assay (Instrumentation Laboratory), Direct Thrombin Inhibitor Assay (Siemens), Technoclot DTI (Technoclone).
Results:
Methods showed variable agreement with the Hemoclot Thrombin Inhibitors assay used as reference test, with modest under- or overestimations (Bland-Altman bias from -17.3 to 4.0 ng/mL). Limits of detection and quantification varied depending on the assay (4-52 and 7-82 ng/mL, respectively). Between-run precision and accuracy were good for all methods for both quality control levels. Assay's repeatability assessed at very low dabigatran concentrations (from 10 to 60 ng/mL) was also acceptable, variability generally increased at lower drug levels.
Conclusion:
The five dabigatran-specific assays evaluated in this study provided reliable assessment of dabigatran plasma levels, although showing different performances.
Related Concept Videos
Concentration Cells
Consider the following voltaic cell:
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Expressing Solution Concentration
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
Calculating Equilibrium Concentrations
A more...

