Identification of inhaler technique errors with a routine procedure in Portuguese community pharmacy
M Margarida Castel-Branco1, Ana Fontes2, Isabel V Figueiredo3
1Laboratory of Pharmacology and Pharmaceutical Care, Faculty of Pharmacy, University of Coimbra, Coimbra (Portugal). mmcb@ci.uc.pt.
Background:
A correct selection of drugs prescribed, but also the choice of the appropriate inhaler device, is crucial for the control of respiratory diseases.
Objective:
To evaluate the inhaler technique and identify potential errors of patients when treated with inhalers by testing a routinary procedure to be implemented in any community pharmacy.
Methods:
Adults with asthma/COPD and under inhalation therapy were invited to demonstrate how they use their inhalers. After direct observation it was registered whether all the sequential steps included in the summary of product characteristics (SmPC) were performed.
Results:
The study involved 67 patients from 4 community pharmacies (Portugal central region): 34 (50.7%) males, 65.4 (SD=18.28) years old, 42 (62.7%) with COPD, and 23 (34.3%) using more than one inhaler. The 67 patients used 95 inhalers, comprising: 57 (60.0%) multiple dose DPI (dry powder inhalers), 18 (18.9%) single dose DPI, 16 (16.8%) pMDI (pressurized metered dose inhalers), 2 (2.1%) pMDI+spacer and 2 (2.1%) SMI (soft mist inhalers). No errors were made only by 9 (13.4%) patients. In the 75 DPIs techniques, the most frequent errors were 'no previous forced expiration' (46=61.3%) and 'no 10s apnea after inhalation' (51=68.0%); in the 16 pMDIs techniques common errors were 'lack of hand-lung coordination' (7=43.8 %), 'no previous forced exhalation' (8=50.0%) and 'no apnea after inhalation' (10=62.5%). After inhaling from 56 devices containing corticosteroids, 34 (60.7%) of the patients did not wash their mouth.
Conclusion:
The study demonstrated the possibility of performing this procedure routinely in Portuguese community pharmacies and also its utility, since 58 (87%) of patients had at least one error during the inhalers use.
Related Concept Videos
What are Populations and Communities?
Inhaled Medications
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Random Error