Validation of Modelflow Estimates of Cardiac Output in Hemodialysis Patients
Clare MacEwen1,2, Sheera Sutherland1, Jonathan Daly2
1Oxford Kidney Unit, Oxford University Hospitals NHS Trust, Oxford, UK.
Abstract:
Volume-clamp technology (e.g. Finometer) has become a popular method of collecting continuous, non-invasive, hemodynamic information during hemodialysis. There is minimal data validating the technique in this patient group. A gold standard cardiac output measurement can be obtained using ultrasound dilution in patients with arterio-venous fistulae. Continuous cardiac output was measured in 124 hemodialysis sessions in 27 patients using a volume-clamp device (Finometer PRO). Ultrasound dilution measurement was first taken at baseline (Transonic HD03), then used to calibrate the Finometer. Ultrasound dilution measurement was repeated 2 h into hemodialysis to assess drift following calibration. Pearson's correlation and Bland-Altman statistics, modified for repeated measures, were used to assess agreement between methods. Linear mixed models were constructed to identify factors that could explain session-level and patient-level variation in agreement. For baseline cardiac output before calibration, agreement between volume-clamp and ultrasound dilution measurements was poor, at 25 ± 75% (correlation 0.26, P < 0.001). There was significant variation in agreement between patients, with age, peripheral vascular disease and hemodialysis vintage contributing to poorer agreement. For cardiac output 2 h after calibration, agreement was -5.2 ± 57.5% (correlation 0.6, P < 0.001). Dynamic changes in blood pressure and fluid balance during hemodialysis resulted in greater drift over time after calibration. There was a large error, both random and systematic, in volume-clamp estimates of absolute, pre-calibration cardiac output in this prevalent hemodialysis population. There was minimal bias and reasonable correlation for cardiac output 2 h post-calibration, but limits of agreement remained too wide to meet current clinical standards.
More Related Videos
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Hemodialysis I: Introduction