Related Experiment Video
Updated: Feb 15, 2026

Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
[Research on the Angle and Effective Depth of Deep Acupuncture at Baliao Points by Three-dimensional Reconstruction
Xun Jin1, Shu-Qing Ding2, Fei-Yue Shi3
1Nanjing University of Chinese Medicine, Nanjing 210029, China.
Objective:
To explore the needle insertion parameters of deep acupuncture at Baliao points for clinic and teaching.
Methods:
A retrospective analysis of 100 cases of prone pelvic CT from January to June 2016 in Nanjing Hospital was carried out. The 3 D images were scanned with continuous 5 mm slice thickness. The optimum needle angle is defined as the angle of the needle along the central axis of sacral anterior and posterior hole, and the angle between the needle body and the skin surface and the center line of the body was observed. The effect needle depth is defined as the thickness of the sacral back soft tissue plus 1/2 sacral depth, to observe the best needle angle of deep acupuncture parameters of Baliao points.
Results:
For deep acupuncture at Baliao, the oblique thorn method should be used with the needle-point toward the inner bottom. The best insertion angle between needle body and skin surface is: Shangliao(BL 31) (61.04±12.15)°, Ciliao(BL 32) (57.57±10.01)°, Zhongliao(BL 33) (58.25±8.69)°, Xialiao(BL 34) (54.39±10.94)°. The optimum angle of insertion between the needle body and the posterior midline of the human body is: BL 31 (24.54±6.21)°, BL 32 (18.58±7.76)°, BL 33 (17.36±7.90)°, BL 34 (30.73±9.45)°. The effective insertion depth show a decreasing trend: BL 31 (58.16±12.43) mm, BL 32 (44.57±11.55) mm, BL 33 (33.96±10.74) mm, BL 34 (31.13±10.94) mm. The effective depth is positively correlated with BMI, and has no correlation with gender and weight.
Conclusions:
The study of the parameters of needle insertion should be taken into account both clinical efficacy and safety, and CT three-dimensional reconstruction can accurately, rationally and scientifically perform acupoint anatomical measurements.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Design Example: Traverse Angle Computations
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Uniform Depth Channel Flow

