Related Experiment Video
Updated: Feb 15, 2026

Assessment and Evaluation of the High Risk Neonate: The NICU Network Neurobehavioral Scale
Published on: August 25, 2014
Assessment of preeclampsia risk by use of serum ionized magnesium-based equation
Chatchai Kreepala1, Maethaphan Kitporntheranunt2, Worrawat Sangwipasnapaporn3
1a Department of Internal Medicine, Faculty of Medicine , Srinakharinwirot University , Ongkharak , Thailand.
Background:
Preeclampsia is a common medical complication in pregnancy. It has been reported to be associated with decreased serum magnesium levels. However, there has not been evidence demonstrating utilization of change in magnesium for prediction of preeclampsia. The purpose of this study was to develop magnesium fraction-based equations which took other significant clinical risk factors into consideration for prediction of preeclampsia.
Methods:
We collected serum total and ionized magnesium ionized magnesium levels from 84 pregnant women diagnosed with preeclampsia after week 20 of pregnancy. The ionized magnesium fraction was then calculated by the percentage ratio of ionized and total magnesium level.
Results:
Sixty-four (76.19%) women had normal pregnancy and 20 (23.81%) developed preeclampsia. The ionized magnesium fraction was significantly lower in preeclampsia group (23.95 ± 4.7% vs. 26.28 ± 2.3%, p = .04). Additionally, lower ionized magnesium fraction (24.67%), teenage and elderly primigravida were significantly associated with preeclampsia (OR = 4.41, 95% CI: 1.46-13.40, OR = 5.47, 95% CI: 1.85-35.42 and OR = 11.11, 95% CI: 1.09-113.78, respectively). Consequently, we attempted to develop ionized magnesium fraction-based equations calculate risk scores for preeclampsia. The area of ROC for predictive accuracy of the model was 0.77 (p < .001) and ROC suggested that the score of 0.27 would be a threshold for screening preeclampsia with 70% sensitivity and 81% specificity.
Conclusions:
Ionized magnesium fraction may have been appropriate for screening of preeclampsia. We suggested blood testing on total and ionized magnesium concentrations as well as calculation of ionized magnesium fraction in addition to routine antenatal care for better screening of the disease.
Related Concept Videos
Ionization Energy
Balancing Redox Equations
Chemical Equations
The Nernst Equation
The interconnection between standard cell potentials and various thermodynamic parameters such as the standard free energy change ΔG° and equilibrium constant K has been previously explored. For example, a redox reaction involving zinc(II) and tin(II) ions at 1 M concentration with Eºcell = +0.291 V and ΔG° = −56.2 kJ is spontaneous.
Henderson-Hasselbalch Equation
Thermochemical Equations