Accuracy of non-invasive blood pressure measurements in obese patients
Abigail Arnold1, Amanda McNaughton2
1Second Year BSc Adult Nursing Student, King's College London.
Abstract:
This article describes an evidence-based literature review, comparing upper arm and forearm blood pressure measurements using non-invasive devices on obese patients. The focus on blood pressure monitoring was in response to regularly witnessing inappropriately applied blood pressure cuffs on obese patient's upper arms in practice. An inaccurately obtained blood pressure measurement can result in the misdiagnosis and treatment of hypertension. As the prevalence of obesity grows worldwide, healthcare settings need to ensure they have the necessary equipment and trained staff to accurately measure obese patients' blood pressure. The aim of this review was to identify whether a forearm measurement provided a suitable alternative to upper arm measurements. The article discusses the development and execution of a search strategy, as well as the critical appraisal of a selected article. The results of the review demonstrated that forearm blood pressure measurements in obese patients do not replace upper arm blood pressure measurements taken with an appropriate cuff. It is recommended that further research is undertaken in order to identify suitable alternatives for obtaining an accurate non-invasive blood pressure measurement in obese patients.
Related Concept Videos
Measurement of Blood Pressure
Uncertainty in Measurement: Accuracy and Precision
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Drug Dosing: Obese Patients
Blood Pressure