Related Experiment Video
Updated: Feb 15, 2026

Author Spotlight: Assessing the Cardiovascular Profile of Patients with Metabolic Syndrome
Published on: September 27, 2024
Subject-specific pulse wave propagation modeling: Towards enhancement of cardiovascular assessment methods
Jan Poleszczuk1, Malgorzata Debowska1, Wojciech Dabrowski2
1Department for Mathematical Modeling of Physiological Processes, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland.
Abstract:
Cardiovascular diseases are the leading cause of death worldwide. Pulse wave analysis (PWA) technique, which reconstructs and analyses aortic pressure waveform based on non-invasive peripheral pressure recording, became an important bioassay for cardiovascular assessment in a general population. The aim of our study was to establish a pulse wave propagation modeling framework capable of matching clinical PWA data from healthy individuals on a per-subject basis. Radial pressure profiles from 20 healthy individuals (10 males, 10 females), with mean age of 42 ± 10 years, were recorded using applanation tonometry (SphygmoCor, AtCor Medical, Australia) and used to estimate subject-specific parameters of mathematical model of blood flow in the system of fifty-five arteries. The model was able to describe recorded pressure profiles with high accuracy (mean absolute percentage error of 1.87 ± 0.75%) when estimating only 6 parameters for each subject. Cardiac output (CO) and stroke volume (SV) have been correctly identified by the model as lower in females than males (CO of 3.57 ± 0.54 vs. 4.18 ± 0.72 L/min with p-value < 0.05; SV of 49.5 ± 10.1 vs. 64.2 ± 16.8 ml with p-value = 0.076). Moreover, the model identified age related changes in the heart function, i.e. that the cardiac output at rest is maintained with age (r = 0.23; p-value = 0.32) despite the decreasing heart rate (r = -0.49; p-value < 0.05), because of the increase in stroke volume (r = 0.46; p-value < 0.05). Central PWA indices derived from recorded waveforms strongly correlated with those obtained using corresponding model-predicted radial waves (r > 0.99 and r > 0.97 for systolic (SP) and diastolic (DP) pressures, respectively; r > 0.77 for augmentation index (AI); all p-values < 0.01). Model-predicted central waveforms, however, had higher SP than those reconstructed by PWA using recorded radial waves (5.6 ± 3.3 mmHg on average). From all estimated subject-specific parameters only the time to the peak of heart ejection profile correlated with clinically measured AI. Our study suggests that the proposed model may serve as a tool to computationally investigate virtual patient scenarios mimicking different cardiovascular abnormalities. Such a framework can augment our understanding and help with the interpretation of PWA results.
Related Concept Videos
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Propagation of Waves
Consider a scenario where a wave propagates from a string of low linear mass density to a string of high linear mass density. In such a case, the reflected wave is out of phase with respect to the incident wave, however the...
Propagation Speed of Electromagnetic Waves
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Pulse Assessment Sites
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: