Related Experiment Video
Updated: Feb 15, 2026

Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents
Published on: October 26, 2016
Risk Factors for Primary Failure of Metallic Ureteral Stents: Experience from a Tertiary Center
Jui-Shan Hsu1,2, Chao-Yuan Huang3, Kao-Lang Liu1
1Department of Medical Imaging, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei, Taiwan.
Abstract:
We provide primary patency rate of metallic ureteral stents in cancer patients and investigate the factors affecting primary patency. All cancer patients who had received metallic stents for malignant ureteral obstruction between July 2009 and November 2012 in our institute were included. No patients were excluded. Patient profiles, imaging studies, and laboratory data were collected. Patient profiles included age, gender, body height, body weight, body mass index, cancer types, treatment for cancer, response to cancer treatment, methods of stent insertion, and prior ordinary stents. Imaging studies included renal ultrasonography, antegrade pyelography, CT, and MRI. Laboratory data included urinalysis, urine culture, and serum creatinine. Complications were defined according to the Clavien-Dindo classification. Primary patency was defined as a complete resolution or downgrading of hydronephrosis shown by imaging studies or success in the removal of a preexisting nephrostomy tube; otherwise the procedure was considered a primary failure. The primary endpoint was the primary patency rate of the stents. The secondary endpoints were risk factors for primary stent failure. A total of 124 stents were inserted into 96 patients with malignant ureteral obstruction. There were no grade 3/4 complications. The overall primary patency rate was 87.9% (109/124). In univariate analysis, antegrade insertion (OR = 24.15, p-value = 0.0086) and urinary tract cancer (OR = 4.18, p-value = 0.0164) were significantly associated with primary failure. Those with prior ordinary stents (OR = 0.20, p-value = 0.0158) or response to cancer treatment (OR = 0.25, p-value = 0.0228) were associated with stent patency. In multivariate analysis, antegrade insertion (OR = 22.04, p-value = 0.0041) and response to cancer treatment (OR = 0.15, p-value = 0.01081) remained significant factors. In this large cohort of cancer patients requiring urinary diversion to preserve renal function, several factors were associated with the success rate of metallic stents.
Related Concept Videos
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Other Factors Affecting Respiration Centers
However, the ability to hold one's breath voluntarily is not limitless. When the CO2 concentration in the blood reaches a critical...
Drug Toxicity: Risk factors
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated....
Tertiary Healthcare System
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....