Related Experiment Video
Updated: Feb 15, 2026

Milk Collection in the Rat Using Capillary Tubes and Estimation of Milk Fat Content by Creamatocrit
Published on: December 16, 2015
Milk-flow data collected routinely in an automatic milking system: an alternative to milking-time testing in the
Håvard Nørstebø1,2, Amira Rachah3, Gunnar Dalen3,4
1Department of Production Animal Clinical Sciences, Faculty of Veterinary Medicine, Norwegian University of Life Sciences, PO Box 8146 Dep, 0033, Oslo, Norway. havard.norstebo@nmbu.no.
Background:
Having a poor teat-end condition is associated with increased mastitis risk, hence avoiding milking machine settings that have a negative effect on teat-end condition is important for successful dairy production. Milking-time testing (MTT) can be used in the evaluation of vacuum conditions during milking, but the method is less suited for herds using automatic milking systems (AMS) and relationships with teat end condition is poorly described. This study aimed to increase knowledge on interpretation of MTT in AMS and to assess whether milk-flow data obtained routinely by an AMS can be useful for the management of teat-end health. A cross-sectional study, including 251 teats of 79 Norwegian Red cows milked by AMS was performed in the research herd of the Norwegian University of Life Sciences. The following MTT variables were obtained at teat level: Average vacuum level in the short milk tube during main milking (MTVAC), average vacuum in the mouthpiece chamber during main milking and overmilking, teat compression intensity (COMPR) and overmilking time. Average and peak milk flow rates were obtained at quarter level from the AMS software. Teat-end callosity thickness and roughness was registered, and teat dimensions; length, and width at apex and base, were measured. Interrelationships among variables obtained by MTT, quarter milk flow variables, and teat dimensions were described. Associations between these variables and teat-end callosity thickness and roughness, were investigated.
Results:
Principal component analysis showed clusters of strongly related variables. There was a strong negative relationship between MTVAC and average milk flow rate. The variables MTVAC, COMPR and average and peak milk flow rate were associated with both thickness and roughness of the callosity ring.
Conclusions:
Quarter milk flow rate obtained directly from the AMS software was useful in assessing associations between milking machine function and teat-end condition; low average milk flow rates were associated with a higher likelihood of the teat having a thickened or roughened teat-end callosity ring. Since information on milk flow rate is readily available from the herd management system, this information might be used when evaluating causes for impaired teat-end condition in AMS.
Related Concept Videos
Data Collection II
Data Collection I
Data Collection by Experiments
An example of the experimental method is a public...
Data Collection by Survey
Data Collection by Observations
An astronomer viewing the motion and brightness of stars in the sky and recording the data is an example of observational data collection. A botanist recording...
Data Collection III
The principles to begin the physical assessment include conducting a comprehensive or problem-related history in a quiet, well-lit room, emphasizing privacy and comfort for the...