Related Experiment Video
Updated: Feb 15, 2026

Author Spotlight: Advancing SERS Technology: Au@Carbon Dot Nanoprobes for Label-Free Analysis and Imaging
Published on: June 9, 2023
Carbon dots as absorbance promoter probes for detection of Cu(ii) ions in aqueous solution: central composite design
S A R Shahamirifard1, M Ghaedi, M Montazerozohori
1Chemistry Department, Yasouj University, Yasouj 75918-74831, Iran. m_ghaedi@mail.yu.ac.ir.
Abstract:
In this work, the use of carbon dots (CDs) as a complexing agent and sensitizer in a polymeric matrix for determination of copper(ii) by UV-vis spectroscopy is reported for the first time. A new and highly selective Schiff base, namely, (N',N'''E,N',N'''E)-N',N'''-((((2-hydroxypropane-1,3-diyl)bis(oxy))bis(2,1-phenylene))bis(methan-ylylidene))di(isonicotinohydrazide) (NHBMDI), was also incorporated in the polymeric matrix. For the first time, the membrane composition of the proposed optical sensor including NHBMDI as the ionophore, tetraphenylborate (NaTPB) as the anionic additive, dibutyl phthalate (DBP) as the plasticizer and polyvinyl chloride (PVC) as the immobilizer was optimized through central composite design combined with the desirability function approach (DFA) because this method saves material and time consumption and is therefore cost effective. The synthesized CDs were characterized by transmission electron microscopy (TEM) and scanning electron microscopy (SEM). The fluorescence quantum yield of the synthesized CDs was found to be 6.4% by using quinine sulfate as the reference. The characterization of the prepared membrane sensor was investigated by field emission scanning electron microscope (FE-SEM) and atomic force microscopy (AFM).The response of the optode was based on the strong absorbance of NHBMDI and CDs upon exposure to Cu(ii) ions with the maximum wavelength at 371 nm. The proposed sensor exhibited a linear response in the concentration range of 1.2 × 10-6-4.56 × 10-5 mol L-1 with a detection limit of 7.1 × 10-7 mol L-1, which is lower than U.S. Environmental Protection Agency's defined limit (20 μM). Furthermore, the proposed optode displayed good selectivity toward Cu(ii) ions in comparison with common coexisting cations with satisfactory repeatability and reproducibility. The sensor was applied successfully for determination of copper(ii) ions in water samples.
Related Concept Videos
Chemical Reactions in Aqueous Solutions
Aqueous Solutions and Heats of Hydration
When ionic compounds dissolve in water, the ions in the solid separate and disperse uniformly throughout the solution because water molecules surround and solvate the ions, reducing the strong electrostatic forces between them. This process...
Leveling Effect and Non-Aqueous Acid-Base Solutions
The Leveling Effect of a Solvent
A generic acid (HA) reacts with the generic base (B-) to yield the corresponding conjugate base (A-) and conjugate acid (HB):
General Properties of Solutions
Solution Composition During Acid/Base Titrations
The α0 and α1 values...
Composition of Polyprotic Acid Solutions as a Function of pH
A graph with the alpha values is plotted against the volume of...

