Investigation of an appropriate contrast-enhanced CT protocol for young patients following the Fontan operation

Motoo Nakagawa1, Yoshiyuki Ozawa2, Norikazu Nomura3

  • 1Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, Japan. lmloltlolol@gmail.com.

Insights

Contrast-enhanced CT scans are adequate for evaluating children after the Fontan operation. Both 60-second and 70-second delayed phases effectively assess intraconduit patency in congenital heart disease patients.

Area of Science:

  • Medical Imaging
  • Pediatric Cardiology
  • Radiology

Background:

  • Children with congenital heart diseases (CHDs) require post-Fontan operation follow-up.
  • Complications like conduit occlusion necessitate imaging surveillance.
  • Contrast-enhanced CT is a key tool for assessing these complications.

Purpose of the Study:

  • To develop an optimal contrast-enhanced CT protocol.
  • To evaluate the adequacy of delayed scanning phases for children post-Fontan operation.
  • To ensure accurate assessment of conduit patency.

Main Methods:

  • 29 dual-source CT examinations were performed on 26 pediatric patients (aged 2-11 years) post-Fontan operation.
  • Contrast medium was administered intravenously.
  • Scanning occurred at 60 or 70-second delayed phases to evaluate conduit enhancement.

Main Results:

  • Conduit enhancement showed similar CT numbers at both 60 and 70 seconds (185 ± 46 HU vs. 185 ± 31 HU).
  • Statistical analysis revealed no significant difference between the two delayed phases (P=0.97).
  • Both phases provided comparable visualization of the conduits.

Conclusions:

  • Both 60-second and 70-second delayed phases are suitable for contrast-enhanced CT.
  • These protocols adequately evaluate intraconduit patency in pediatric patients after the Fontan operation.
  • The findings support the use of either delayed phase for routine follow-up imaging.
Abstract

Related Concept Videos

Radiological Investigation I: X-ray and CT01:30

Radiological Investigation I: X-ray and CT

Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and...
1.2K
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
14.5K
Real Number Operations01:27

Real Number Operations

The concept of real numbers includes all the values that can be represented on a continuous number line. The system began with basic counting values used for enumeration. It later expanded to include values that represent the absence of quantity and opposites of the counting values. When situations required expressing parts of a whole or dividing quantities evenly, values capable of representing such proportions were developed. When written using decimal notation, these values can end or repeat...
349
Operational Amplifiers01:17

Operational Amplifiers

The operational amplifier, often referred to as an op-amp, is a multifaceted building block of a circuit. This electronic component functions like a voltage-controlled voltage source and can also be used to create a voltage- or current-controlled current source. The design of an operational amplifier enables it to execute mathematical operations when external components like resistors and capacitors are linked to its terminals. An op-amp has the capacity to sum signals, amplify a signal,...
2.0K
Vector Operations01:20

Vector Operations

Vectors are physical quantities that have both magnitude and direction. The vector operations include addition, subtraction, and scalar multiplication.
A vector multiplied by a scalar value is called scalar multiplication. The result obtained is a new vector with a different magnitude. If the scalar is positive, the direction of the vector remains the same, but if it is negative, the direction of the vector is reversed. For example, the product of the mass and velocity yields the momentum.
2.3K
Operant Conditioning01:21

Operant Conditioning

Operant conditioning, a key concept in behavioral psychology, involves using reinforcement and punishment to alter the likelihood of a behavior being repeated. B.F. introduced this type of conditioning. Skinner focused on voluntary behaviors and the consequences that follow them, influencing whether these behaviors will be strengthened or diminished.
Reinforcement in operant conditioning can be positive or negative, both of which serve to increase the likelihood of a behavior. Positive...
2.9K